毛片在线视频观看,一级日韩免费大片,在线网站黄色,澳门在线高清一级毛片

薈聚奇文、博采眾長(zhǎng)、見(jiàn)賢思齊
當(dāng)前位置:公文素材庫(kù) > 計(jì)劃總結(jié) > 計(jì)劃方案 > 暖通空調(diào)設(shè)計(jì)方案經(jīng)驗(yàn)總結(jié)_secret

暖通空調(diào)設(shè)計(jì)方案經(jīng)驗(yàn)總結(jié)_secret

網(wǎng)站:公文素材庫(kù) | 時(shí)間:2019-05-29 04:40:20 | 移動(dòng)端:暖通空調(diào)設(shè)計(jì)方案經(jīng)驗(yàn)總結(jié)_secret

暖通空調(diào)設(shè)計(jì)方案經(jīng)驗(yàn)總結(jié)_secret

做暖通方案設(shè)計(jì)方案對(duì)暖通空調(diào)工程設(shè)計(jì)的成敗優(yōu)劣關(guān)系重大。近年來(lái),隨著科學(xué)技術(shù)的迅速發(fā)展以及對(duì)節(jié)能和環(huán)保要求的不斷提高,暖通空調(diào)領(lǐng)域中新的設(shè)計(jì)方案大量涌現(xiàn),針對(duì)同一個(gè)設(shè)計(jì)項(xiàng)目,往往可以有幾種、十幾種甚至幾十種不同的設(shè)計(jì)方案可以選擇,設(shè)計(jì)人員不得不進(jìn)行大量的方案比較和優(yōu)選的工作,設(shè)計(jì)方案技術(shù)經(jīng)濟(jì)性比較正在成為影響暖通空調(diào)設(shè)計(jì)質(zhì)量和效率的一項(xiàng)重要工作。暖通空調(diào)設(shè)計(jì)方案的評(píng)價(jià)因素很多,一些因素很難定量表述,許多因素又不具可比性,每種設(shè)計(jì)方案往往都有各自的優(yōu)缺點(diǎn),面對(duì)眾多的設(shè)計(jì)方案,由于考慮問(wèn)題的角度不同,各方的看法往往各不相同,甚至大相徑庭。目前在設(shè)計(jì)方案比較中存在的一些混亂狀況使設(shè)計(jì)人員無(wú)所適從。如何對(duì)暖通空調(diào)設(shè)計(jì)方案進(jìn)行科學(xué)的比較和優(yōu)選,是暖通空調(diào)設(shè)計(jì)人員在實(shí)際設(shè)計(jì)工作中經(jīng)常遇到的一個(gè)重要技術(shù)難題。筆者根據(jù)從事設(shè)計(jì)、審圖和方案評(píng)審工作的一些體會(huì),對(duì)暖通空調(diào)設(shè)計(jì)方案比較中應(yīng)注意的一些問(wèn)題進(jìn)行粗淺的分析。1可行性和可靠性問(wèn)題能夠滿足使用要求,這是方案可行性應(yīng)考慮的主要問(wèn)題。設(shè)計(jì)方案應(yīng)符合國(guó)家和當(dāng)?shù)卣嘘P(guān)法規(guī)和規(guī)范的要求,包括有關(guān)環(huán)境保護(hù)的要求;設(shè)計(jì)方案應(yīng)能滿足有關(guān)方面的要求(如供電、供氣、供水、供熱等),并應(yīng)特別顧及這些條件的長(zhǎng)期、變化情況。例如采用水源熱泵設(shè)計(jì)方案時(shí)應(yīng)考慮當(dāng)?shù)氐刭|(zhì)情況、地下水資源的現(xiàn)狀和變化趨勢(shì)、冬季熱負(fù)荷和夏季冷負(fù)荷不平衡所產(chǎn)生的熱(冷)蓄積效應(yīng)等問(wèn)題。對(duì)于溫濕度等參數(shù)要求較高或比較特殊的工藝性暖通空調(diào)設(shè)計(jì)項(xiàng)目,應(yīng)對(duì)設(shè)計(jì)方案進(jìn)行全年工況分析,以確保其在全年各種室外氣象條件下的適應(yīng)性。對(duì)于一些無(wú)法采用標(biāo)準(zhǔn)設(shè)備的特殊情況,對(duì)非標(biāo)準(zhǔn)設(shè)備應(yīng)提出詳細(xì)的參數(shù)要求,并且所提出的參數(shù)要求應(yīng)合理可行。能否有足夠的機(jī)房面積也是評(píng)判設(shè)計(jì)方案可行性必須考慮的問(wèn)題,尤其是對(duì)于一些改造工程和建筑面積比較緊張的情況。對(duì)于一些要求全年保證室內(nèi)空氣參數(shù)的重要工程以及空調(diào)系統(tǒng)故障停機(jī)將產(chǎn)生嚴(yán)重?fù)p失的場(chǎng)所,如航天發(fā)射場(chǎng),應(yīng)考慮系統(tǒng)中設(shè)備的工作可靠性和備份問(wèn)題,進(jìn)行系統(tǒng)工作可靠性分析。在這種情況下,室外氣象參數(shù)和安全系數(shù)的確定也應(yīng)特殊考慮。2經(jīng)濟(jì)性比較問(wèn)題經(jīng)濟(jì)性比較是目前暖通空調(diào)方案比較中考慮最多的一個(gè)問(wèn)題。在經(jīng)濟(jì)性比較時(shí)首先應(yīng)注意比較基準(zhǔn)必須一致。應(yīng)采用相同的設(shè)計(jì)要求、使用情況、設(shè)備檔次、能源價(jià)格、舒適狀況、美觀情況等基準(zhǔn)條件進(jìn)行比較,這樣才能保證方案比較結(jié)果的科學(xué)性和合理性。如果對(duì)采用名牌設(shè)備和采用低檔設(shè)備的方案進(jìn)行經(jīng)濟(jì)性比較,顯然是不合理的;如果不考慮舒適性的區(qū)別,對(duì)有新風(fēng)供應(yīng)和沒(méi)有新風(fēng)供應(yīng)的方案進(jìn)行經(jīng)濟(jì)性比較,顯然不可能做出正確的選擇;如果不考慮美觀性和舒適性進(jìn)行經(jīng)濟(jì)性比較,對(duì)集中式空調(diào)方案顯然是不公平的。一次投資是投資方最為關(guān)注的一個(gè)參數(shù),在計(jì)算投資時(shí)應(yīng)全面準(zhǔn)確、不能漏項(xiàng)。暖通空調(diào)設(shè)計(jì)方案的一次投資不僅包括各種設(shè)備、管道、材料的投資,而且應(yīng)包括各種相關(guān)收費(fèi)(如熱力入網(wǎng)費(fèi)、用電設(shè)備增容費(fèi)、天然氣的氣源費(fèi)等),相應(yīng)的安裝、調(diào)試費(fèi)用,相關(guān)的工程管理等各種收費(fèi),相關(guān)水處理和配電與控制投資,機(jī)房土建投資與相應(yīng)室外管線的費(fèi)用,而這些在實(shí)際設(shè)計(jì)工作中容易被遺漏。由于同一種設(shè)備的生產(chǎn)廠家較多,價(jià)格各異,因此在不同方案經(jīng)濟(jì)性計(jì)算比較時(shí)各種設(shè)備的價(jià)格應(yīng)采用平均價(jià)格。以上都是直接費(fèi)用,在一些情況下間接效益也應(yīng)綜合考慮。如賓館、飯店、寫(xiě)字樓的空調(diào)機(jī)房節(jié)省的面積,作為商業(yè)用房可產(chǎn)生的效益。如果采用貸款進(jìn)行建設(shè),全面的經(jīng)濟(jì)性比較還應(yīng)考慮貸款利率和還貸期限等動(dòng)態(tài)因素。運(yùn)行能耗和運(yùn)行費(fèi)用是暖通空調(diào)設(shè)計(jì)方案技術(shù)經(jīng)濟(jì)性比較必須考慮的重要參數(shù)。運(yùn)行能耗除了應(yīng)計(jì)算暖通空調(diào)主機(jī)(鍋爐和制冷機(jī)等)的能耗外,還應(yīng)計(jì)算其他輔助設(shè)備(如風(fēng)機(jī)和水泵等)的能耗。不能簡(jiǎn)單按照設(shè)備銘牌功率和運(yùn)行時(shí)間的乘積來(lái)計(jì)算能耗而應(yīng)考慮在全年季節(jié)變化的情況下,建筑物實(shí)際負(fù)荷的變化,同時(shí)應(yīng)考慮設(shè)備非標(biāo)準(zhǔn)狀態(tài)下的效率。辦公樓、教學(xué)樓、寫(xiě)字樓和游泳館等建筑物的暖通空調(diào)設(shè)備通常間歇運(yùn)行,其運(yùn)行時(shí)間應(yīng)為扣除停機(jī)時(shí)間后的實(shí)際運(yùn)行時(shí)間。在計(jì)算過(guò)程中應(yīng)注意不同地區(qū)、不同時(shí)期、不同時(shí)段各種能源的價(jià)格可能不同。由于影響因素和不確定因素較多,如何準(zhǔn)確地計(jì)算建筑物暖通空調(diào)設(shè)備全年的實(shí)際能耗和運(yùn)行費(fèi)用,目前仍然是一個(gè)沒(méi)有完全解決的技術(shù)難題。運(yùn)行費(fèi)用除了能耗費(fèi)用如電費(fèi)、燃油費(fèi)、燃煤費(fèi)、燃?xì)赓M(fèi)外,還應(yīng)包括消耗的水費(fèi)、人工費(fèi)等。在經(jīng)濟(jì)性比較時(shí),切忌圖省事可直接采用有關(guān)廠家給出的比較數(shù)據(jù)和結(jié)果。筆者曾發(fā)現(xiàn),對(duì)電供暖的運(yùn)行費(fèi)用,3個(gè)不同設(shè)備(電鍋爐、水源熱泵和戶式燃?xì)夤┡癄t)廠家提供的計(jì)算結(jié)果大相徑庭。通過(guò)對(duì)其計(jì)算過(guò)程的詳細(xì)核對(duì),發(fā)現(xiàn)不同設(shè)備生產(chǎn)廠家由于考慮問(wèn)題的角度不同,計(jì)算中存在一些有利于自己產(chǎn)品、不利于他人產(chǎn)品的失誤或假設(shè)。對(duì)此設(shè)計(jì)人員應(yīng)給予足夠重視,對(duì)廠家提供的數(shù)據(jù)應(yīng)認(rèn)真分析和核對(duì)。在設(shè)計(jì)方案經(jīng)濟(jì)性比較時(shí)應(yīng)綜合考慮投資、運(yùn)行費(fèi)用以及設(shè)備的使用壽命,以相同的使用周期為基準(zhǔn),進(jìn)行綜合經(jīng)濟(jì)性的計(jì)算比較,而不能簡(jiǎn)單地根據(jù)設(shè)備報(bào)價(jià)進(jìn)行比較。對(duì)于同時(shí)有供暖和空調(diào)要求的項(xiàng)目,應(yīng)考慮冬季和夏季設(shè)備綜合利用問(wèn)題,進(jìn)行冬夏季綜合經(jīng)濟(jì)性比較。對(duì)于可以兼供生活熱水的工程,應(yīng)綜合考慮生活熱水供應(yīng)的投資和能耗。3調(diào)節(jié)性和可操作性問(wèn)題暖通空調(diào)系統(tǒng)的容量通常是按接近全年最不利的氣象條件確定的,因此系統(tǒng)應(yīng)有較好的調(diào)節(jié)性能,以適應(yīng)全年負(fù)荷的變化。調(diào)節(jié)性能好的系統(tǒng)方案,如采用VAV空調(diào)系統(tǒng)和VRV變頻空調(diào)系統(tǒng)的方案,其一次投資通常較高,但運(yùn)行能耗較小,在經(jīng)濟(jì)性計(jì)算和比較時(shí)應(yīng)綜合考慮這些因素。對(duì)于部分時(shí)間使用的辦公建筑、寫(xiě)字樓和教學(xué)樓,設(shè)計(jì)方案應(yīng)能適應(yīng)其夜間不工作時(shí)的調(diào)節(jié)要求。設(shè)計(jì)方案的管理操作方便性是用戶十分關(guān)心的問(wèn)題?照{(diào)系統(tǒng)自動(dòng)化水平的提高,可以減少管理人員的數(shù)量和勞動(dòng)強(qiáng)度,從而使人工費(fèi)減少,但使一次投資增加,對(duì)操作人員素質(zhì)的要求提高?照{(diào)系統(tǒng)是否采用自動(dòng)控制,應(yīng)根據(jù)實(shí)際情況和要求,經(jīng)技術(shù)經(jīng)濟(jì)性比較來(lái)確定。對(duì)于大型空調(diào)系統(tǒng)和需要經(jīng)常調(diào)節(jié)控制的設(shè)備較多的工程,宜采用自動(dòng)控制,以減少操作管理的工作量。但自動(dòng)控制系統(tǒng)應(yīng)盡可能簡(jiǎn)化,以提高系統(tǒng)的經(jīng)濟(jì)性和可靠性。對(duì)于只有季節(jié)轉(zhuǎn)換時(shí)才操作的閥門不宜采用自動(dòng)控制。對(duì)于一些各部分不同時(shí)使用的建筑物或各部分出租給不同使用單位的商業(yè)建筑,系統(tǒng)設(shè)置應(yīng)考慮分別管理控制和運(yùn)行費(fèi)用分別統(tǒng)計(jì)交納的要求。4安全性問(wèn)題設(shè)計(jì)方案的安全性是以往考慮較少的問(wèn)題,隨著美國(guó)“911”等恐怖襲擊事件的發(fā)生以及SARS的出現(xiàn)和迅速蔓延,暖通空調(diào)系統(tǒng)的安全性問(wèn)題已經(jīng)成為公眾關(guān)注的焦點(diǎn),在SARS嚴(yán)重流行時(shí)期,人們甚至對(duì)空調(diào)系統(tǒng)產(chǎn)生恐懼而不敢使用,這將對(duì)暖通空調(diào)行業(yè)的發(fā)展產(chǎn)生深遠(yuǎn)的影響。經(jīng)過(guò)對(duì)這些事件的認(rèn)真分析、研究和反思,將會(huì)在工程設(shè)計(jì)、設(shè)備研制、運(yùn)行管理、規(guī)范和技術(shù)措施等諸多方面進(jìn)行改進(jìn),使暖通空調(diào)系統(tǒng)的安全性得以提高。在大中型建筑方案設(shè)計(jì)階段,對(duì)其暖通空調(diào)系統(tǒng)進(jìn)行安全性評(píng)估將是十分必要的。暖通空調(diào)系統(tǒng)的安全性主要包括易燃易爆環(huán)境安全、防火安全、人員環(huán)境安全、重要設(shè)備物品環(huán)境安全、系統(tǒng)設(shè)備運(yùn)行安全5個(gè)方面的問(wèn)題。在設(shè)計(jì)彈藥廠房和庫(kù)房、煤礦等易燃易爆工程的通風(fēng)空調(diào)系統(tǒng)時(shí),安全性成為必須考慮的重要因素,應(yīng)采取相應(yīng)的防爆技術(shù)方案和措施。在設(shè)計(jì)燃油燃?xì)忮仩t房時(shí)應(yīng)考慮可燃性氣體、液體泄漏帶來(lái)的安全性問(wèn)題,應(yīng)設(shè)置可燃性氣體泄漏報(bào)警系統(tǒng)和事故通風(fēng)系統(tǒng),并相互聯(lián)鎖。防火安全問(wèn)題應(yīng)按照有關(guān)防火設(shè)計(jì)規(guī)范來(lái)考慮,在此不作詳述。設(shè)備安全運(yùn)行的問(wèn)題主要包括制冷系統(tǒng)的安全保護(hù)、北方暖通空調(diào)系統(tǒng)冬季防凍、空調(diào)系統(tǒng)電加熱與風(fēng)機(jī)聯(lián)鎖保護(hù)等問(wèn)題。在方案設(shè)計(jì)時(shí)應(yīng)注意考慮暖通空調(diào)系統(tǒng)故障可能對(duì)室內(nèi)重要設(shè)備和物品產(chǎn)生的不利影響,例如,重要機(jī)房、重要資料庫(kù)和文物庫(kù)房不應(yīng)采用在吊頂設(shè)置風(fēng)機(jī)盤管的空調(diào)方案,因?yàn)橐坏┛照{(diào)水系統(tǒng)漏水將造成嚴(yán)重?fù)p失。人員環(huán)境安全主要包括暖通空調(diào)系統(tǒng)對(duì)人體的危害、防止恐怖襲擊和防止傳染性疾病擴(kuò)散這3個(gè)方面的問(wèn)題。采用氨制冷方案時(shí),應(yīng)考慮氨泄漏對(duì)人體的危害。鍋爐房的布局應(yīng)考慮人員安全性問(wèn)題。在防止恐怖襲擊方面和防止傳染性疾病擴(kuò)散方面,應(yīng)注意空調(diào)新風(fēng)口是最薄弱環(huán)節(jié),因此必須采取可靠的防范措施,新風(fēng)口應(yīng)設(shè)置在人員難以接近、不易受到污染的地方。由于全空氣空調(diào)系統(tǒng)回風(fēng)口很多,因此它是最容易遭受恐怖分子生化襲擊的空調(diào)系統(tǒng)形式,如果不采取特殊的措施,它也是最容易造成流行性疾病擴(kuò)散的空調(diào)系統(tǒng)形式。從這方面來(lái)說(shuō),分體空調(diào)、一拖多空調(diào)系統(tǒng)、風(fēng)機(jī)盤管空調(diào)系統(tǒng)的安全性較好。在確定系統(tǒng)新風(fēng)量時(shí),除了要考慮以往的一些因素外,還要考慮在流行性疾病暴發(fā)期間,稀釋室內(nèi)有害病毒濃度的要求。在這方面,應(yīng)注意不要走向另一個(gè)極端,對(duì)空調(diào)系統(tǒng)安全性的過(guò)度恐慌是沒(méi)有必要的。例如,為了防止傳染性疾病擴(kuò)散而采用全新風(fēng)直流系統(tǒng),顯然是不合理的,這將使投資、能耗和運(yùn)行費(fèi)用大大增加,關(guān)鍵是要合理確定系統(tǒng)方案和新風(fēng)量,加強(qiáng)有組織排風(fēng),并采用隔絕式的熱回收裝置、加強(qiáng)對(duì)空氣的過(guò)濾與消毒處理。系統(tǒng)新風(fēng)量應(yīng)能調(diào)節(jié),平時(shí)按正常風(fēng)量運(yùn)行,流行性疾病暴發(fā)期間或室內(nèi)受到生化污染的情況下按較大風(fēng)量運(yùn)行。吊頂暗裝風(fēng)機(jī)盤管的回風(fēng)應(yīng)采用風(fēng)管連接,不應(yīng)采用將吊頂作為靜壓箱的吊頂回風(fēng)方式。另外在表冷器、蒸發(fā)器和冷卻塔等結(jié)露積水、病菌容易繁殖的地方應(yīng)采取可靠的排水和消毒措施。5環(huán)境影響問(wèn)題隨著工業(yè)生產(chǎn)的迅速發(fā)展和人們生活水平的日益提高,環(huán)境保護(hù)問(wèn)題越來(lái)越受到人們的重視,而燃煤鍋爐的排煙又是北方城市大氣的主要污染源,因此北京等大城市對(duì)燃煤鍋爐進(jìn)行了嚴(yán)格的限制,而且限制的區(qū)域不斷擴(kuò)大。在這些區(qū)域內(nèi),環(huán)境影響成為了關(guān)系到設(shè)計(jì)方案可行性的一個(gè)重要因素。在設(shè)計(jì)方案選擇時(shí)應(yīng)特別注意環(huán)境保護(hù)要求不斷提高的趨勢(shì),避免建筑物建成不久就進(jìn)行改造。在空調(diào)設(shè)備選型時(shí),要特別注意各種氟利昂制冷劑替代的進(jìn)程要求,不能選用以已經(jīng)或即將禁用的制冷劑為冷媒的空調(diào)產(chǎn)品。在這方面暖通空調(diào)設(shè)計(jì)人員既要有環(huán)境保護(hù)的責(zé)任感,同時(shí)也要考慮建設(shè)方和用戶的經(jīng)濟(jì)承受能力,不要盲目冒進(jìn),以免給建設(shè)方和用戶增加不必要的經(jīng)濟(jì)負(fù)擔(dān)。在對(duì)設(shè)計(jì)方案進(jìn)行經(jīng)濟(jì)性比較分析時(shí),還應(yīng)綜合考慮暖通空調(diào)設(shè)備的廢氣、廢水、廢渣和噪聲等污染治理的費(fèi)用。如何對(duì)設(shè)計(jì)方案污染物排放的危害、對(duì)臭氧層的破壞和產(chǎn)生的溫室效應(yīng)的危害、系統(tǒng)和設(shè)備全過(guò)程(包括設(shè)備制造、使用和淘汰處理的全過(guò)程)的能源和資源消耗等進(jìn)行全面、科學(xué)、定量的經(jīng)濟(jì)性評(píng)估比較,是一個(gè)需要深入研究的問(wèn)題。6設(shè)計(jì)方案比較中的一些誤區(qū)由于設(shè)計(jì)方案比較是一項(xiàng)影響因素多、專業(yè)技術(shù)性很強(qiáng)的復(fù)雜技術(shù)工作,即使是暖通空調(diào)專業(yè)的設(shè)計(jì)人員,要在眾多設(shè)計(jì)方案中選出最佳方案也非易事,對(duì)于局外人更是霧里看花。目前在該項(xiàng)工作中仍然存在一些認(rèn)識(shí)上的誤區(qū)。例如,認(rèn)為采用最新技術(shù)的設(shè)計(jì)方案就是最佳的設(shè)計(jì)方案,出現(xiàn)不管使用條件而盲目追求新技術(shù)的傾向,甚至以此作為賣點(diǎn)進(jìn)行炒作。實(shí)際上每種方案都有其適用條件和范圍,在其適用范圍之外,先進(jìn)的技術(shù)方案就可能變成不合理甚至是不可行的方案。一種設(shè)計(jì)方案對(duì)某個(gè)工程項(xiàng)目可能是最佳方案,但對(duì)于另一個(gè)工程項(xiàng)目就可能是不可行的方案,因此在方案選擇時(shí)不能趕時(shí)髦、搞攀比。另外往往認(rèn)為投資最低的方案就是最佳方案,但是一次投資低的方案有可能因?yàn)槠溥\(yùn)行費(fèi)用很高或設(shè)備壽命很短,需要經(jīng)常更換,從長(zhǎng)期運(yùn)行來(lái)說(shuō)并不合算。在評(píng)價(jià)設(shè)計(jì)方案時(shí),往往認(rèn)為復(fù)雜的方案就是高水平的方案。但實(shí)際上因?yàn)橄到y(tǒng)越復(fù)雜,通常其設(shè)備越多、投資就越高,系統(tǒng)的可靠性、可操作性、可控性和可維護(hù)性就越差,因此復(fù)雜的方案并不一定就是高水平的設(shè)計(jì)方案,在滿足使用要求的前提下,系統(tǒng)越簡(jiǎn)單越好。此外,在選擇設(shè)計(jì)方案時(shí)切忌不加分析地采用建設(shè)方的意見(jiàn),因?yàn)榻ㄔO(shè)方通常不是暖通空調(diào)專業(yè)設(shè)計(jì)人員,不可能對(duì)設(shè)計(jì)方案進(jìn)行全面技術(shù)經(jīng)濟(jì)性分析比較。因此應(yīng)對(duì)建設(shè)方的意見(jiàn)進(jìn)行認(rèn)真的分析,通過(guò)全面技術(shù)經(jīng)濟(jì)性分析比較來(lái)確定最佳的設(shè)計(jì)方案。7結(jié)語(yǔ)暖通空調(diào)設(shè)計(jì)方案的選擇是一個(gè)直接關(guān)系到暖通空調(diào)工程項(xiàng)目的成敗和經(jīng)濟(jì)效益優(yōu)劣的重要問(wèn)題。暖通空調(diào)設(shè)計(jì)方案的比較和優(yōu)選是一個(gè)涉及面廣、影響因素多的復(fù)雜技術(shù)工作。一個(gè)優(yōu)秀的暖通空調(diào)工程設(shè)計(jì)方案,應(yīng)對(duì)設(shè)計(jì)方案涉及的各種因素進(jìn)行全面的考慮,使其綜合效益最高。綜合考慮的因素越多,通常其方案設(shè)計(jì)的水平越高,同時(shí)其設(shè)計(jì)工作量和難度就越大。但由于目前工程設(shè)計(jì)周期普遍較短、暖通空調(diào)專業(yè)的設(shè)計(jì)收費(fèi)太低、設(shè)計(jì)收費(fèi)與設(shè)計(jì)產(chǎn)生的經(jīng)濟(jì)效益不掛鉤以及一些技術(shù)性問(wèn)題沒(méi)有完全解決等原因,在實(shí)際設(shè)計(jì)工作中往往不能對(duì)設(shè)計(jì)方案進(jìn)行多方案多參數(shù)的綜合對(duì)比分析和優(yōu)化選擇,對(duì)設(shè)計(jì)方案的選擇容易出現(xiàn)片面性和主觀性的問(wèn)題,由此造成的經(jīng)濟(jì)損失是相當(dāng)嚴(yán)重的。這一問(wèn)題應(yīng)引起有關(guān)方面的高度重視,在設(shè)計(jì)管理和技術(shù)研究?jī)蓚(gè)方面均要作大量的工作。在設(shè)計(jì)方案比較選擇時(shí)必須對(duì)工程設(shè)計(jì)項(xiàng)目的各項(xiàng)實(shí)際需求、環(huán)境條件的特點(diǎn)、需求和環(huán)境條件的變化趨勢(shì)等情況進(jìn)行深入調(diào)查研究,對(duì)各種技術(shù)方案的特點(diǎn)、適用條件和范圍進(jìn)行客觀深入的分析,對(duì)暖通空調(diào)各種技術(shù)發(fā)展的方向和趨勢(shì)有深入的了解,尤其必須對(duì)各種設(shè)計(jì)方案的可行性、可靠性、安全性、投資、能耗、運(yùn)行費(fèi)用、調(diào)節(jié)性、操作管理的方便性、環(huán)境影響、舒適性和美觀性等技術(shù)經(jīng)濟(jì)評(píng)價(jià)因素進(jìn)行客觀準(zhǔn)確的計(jì)算和綜合對(duì)比分析。只有這樣才能對(duì)各種設(shè)計(jì)方案進(jìn)行科學(xué)的比較和優(yōu)選,避免因片面性和主觀性帶來(lái)的失誤和經(jīng)濟(jì)損失

擴(kuò)展閱讀:暖通空調(diào)設(shè)計(jì)技術(shù)資料總結(jié)_secret

第一章設(shè)計(jì)參考規(guī)范及標(biāo)準(zhǔn).......................................................................................................4

一、通用設(shè)計(jì)規(guī)范:......................................................................................................................4二、專用設(shè)計(jì)規(guī)范:......................................................................................................................4三、專用設(shè)計(jì)標(biāo)準(zhǔn)圖集:..............................................................................................................5

第二章設(shè)計(jì)參數(shù)..............................................................................................................................5

一、商業(yè)和公共建筑物的空調(diào)設(shè)計(jì)參數(shù)ASHRAE....................................................................5二、舒適空調(diào)之室內(nèi)設(shè)計(jì)參數(shù)日本............................................................................................6三、新風(fēng)量......................................................................................................................................7

1、每人的新風(fēng)標(biāo)準(zhǔn)ASHRAE....................................................................................................72、最小新風(fēng)量和推薦新風(fēng)量UK............................................................................................83、各類建筑物的換氣次數(shù)UK...............................................................................................84、各場(chǎng)所每小時(shí)換氣次數(shù).....................................................................................................94、每人的新風(fēng)標(biāo)準(zhǔn)UK............................................................................................................95、考慮節(jié)能的基本新風(fēng)量(1/s人)(日本)....................................................................106、辦公室環(huán)境衛(wèi)生標(biāo)準(zhǔn)日本...........................................................................................107、民用建筑最小新風(fēng)量.......................................................................................................10

第三章空調(diào)負(fù)荷計(jì)算...................................................................................................................13

一、不同窗面積下,冷負(fù)荷之分布%.........................................................................................13二、負(fù)荷指標(biāo)(估算)(僅供參考)..........................................................................................13三、空調(diào)冷負(fù)荷法估算冷指標(biāo)?照{(diào)冷負(fù)荷法估算冷指標(biāo)(W/m2空調(diào)面積)見(jiàn)下表.....14四、按建筑面積冷指標(biāo)進(jìn)行估算建筑面積冷指標(biāo)...........................................................16五、建筑物冷負(fù)荷概算指標(biāo)香港................................................................................................17六、各類建筑物鍋爐負(fù)荷估算W/m3℃.....................................................................................18七、熱損失概算W/m℃...............................................................................................................18八、冷庫(kù)冷負(fù)荷概算指標(biāo)............................................................................................................18

第四章風(fēng)管系統(tǒng)設(shè)計(jì)...................................................................................................................19

一、通風(fēng)管道流量阻力表............................................................................................................19

1、縮伸軟管摩擦阻力表.......................................................................................................192、鍍鋅板風(fēng)管摩擦阻力表...................................................................................................19二、室內(nèi)送回風(fēng)口尺寸表............................................................................................................22

1、風(fēng)口風(fēng)量冷量對(duì)應(yīng)表.......................................................................................................222、不同送風(fēng)方式的風(fēng)量指標(biāo)和室內(nèi)平均流速ASHRAE......................................................23三、室內(nèi)風(fēng)管風(fēng)速選擇表............................................................................................................23

1、低速風(fēng)管系統(tǒng)的推薦和最大流速m/s............................................................................232、低速風(fēng)管系統(tǒng)的最大允許速m/s....................................................................................233、通風(fēng)系統(tǒng)之流速m/s........................................................................................................24四、室內(nèi)風(fēng)口風(fēng)速選擇表............................................................................................................24

1、送風(fēng)口風(fēng)速.......................................................................................................................242、以噪音標(biāo)準(zhǔn)控制的允許送風(fēng)流速m/s............................................................................253、推薦的送風(fēng)口流速m/s....................................................................................................254、送風(fēng)口之最大允許流速m/s............................................................................................255、回風(fēng)口風(fēng)速.......................................................................................................................256、回風(fēng)格柵的推薦流速m/s................................................................................................26

第1頁(yè)共95頁(yè)7、百葉窗的推薦流速m/s....................................................................................................268、逗留區(qū)流速與人體感覺(jué)的關(guān)系.......................................................................................269、頂棚散流器送風(fēng)量...........................................................................................................2610、側(cè)送風(fēng)口送風(fēng)量.............................................................................................................27五、室內(nèi)風(fēng)口的簡(jiǎn)單布............................................................................................................29

1、送風(fēng)口布間距...............................................................................................................292、標(biāo)準(zhǔn)型號(hào)風(fēng)盤所接散流器的尺寸表-辦公室.................................................................293、散流器布.......................................................................................................................294、空調(diào)房間允許最大送風(fēng)溫差℃.......................................................................................305、工藝性空氣調(diào)節(jié)空調(diào)房間允許最大送風(fēng)溫差..............................................................306.1、廚房通風(fēng)問(wèn)題...............................................................................................................306.2如何確定廚房的通風(fēng)量..................................................................................................306.3廚房通風(fēng)設(shè)計(jì)中的幾個(gè)問(wèn)題..........................................................................................32

7、消聲器、靜壓箱總結(jié)............................................................................................................35

8.風(fēng)管貼吸音材料風(fēng)道的衰減量(日本).........................................................................369.風(fēng)管的自然衰減量(只有直風(fēng)道dB/m,其它都是dB)...............................................36

六、防排煙設(shè)計(jì)...............................................................................................................................37

第五章管道系統(tǒng)設(shè)計(jì)...................................................................................................................41

一、空調(diào)管路系統(tǒng)的設(shè)計(jì)原則....................................................................................................41二、管路系統(tǒng)的管材....................................................................................................................42三、供回水總管上的旁通閥與壓差旁通閥的選擇....................................................................42四、空調(diào)水系統(tǒng)管徑的確定........................................................................................................44五、冷凍水泵揚(yáng)程估算方法........................................................................................................45

1、水泵揚(yáng)程簡(jiǎn)易估算法.......................................................................................................462、冷凍水泵揚(yáng)程實(shí)用估算方法...........................................................................................463、水泵揚(yáng)程設(shè)計(jì)...................................................................................................................48六、冷卻水系統(tǒng)的設(shè)計(jì)................................................................................................................48

1、冷卻水系統(tǒng)的補(bǔ)水量.......................................................................................................482、冷卻水循環(huán)系統(tǒng)設(shè)計(jì)中應(yīng)注意的幾個(gè)問(wèn)題:...............................................................49七、冷凝水管道設(shè)計(jì)....................................................................................................................49八、分汽缸、分水器、集水器尺寸的確定................................................................................50九、膨脹水箱的容積計(jì)算............................................................................................................53十、空壓管道管徑選擇表............................................................................................................55十一、空調(diào)水處理系統(tǒng)................................................................................................................56十二、保溫....................................................................................................................................56十三、閥門選用............................................................................................................................57

第六章空調(diào)設(shè)備選型...................................................................................................................58

一、機(jī)組選型................................................................................................................................58二、機(jī)組選型案例........................................................................................................................58三、輔助設(shè)備................................................................................................................................59

1、冷卻塔...............................................................................................................................592、水泵的選型:.....................................................................................................................593、熱泵中央空調(diào)系統(tǒng)水量計(jì)算...........................................................................................604、冷凍水和冷卻水流量估算...............................................................................................615、設(shè)備水壓力降估算(日本)..........................................................................................61

第2頁(yè)共95頁(yè)6、制冷機(jī)冷卻水量估算表...................................................................................................61

第七章自控系統(tǒng)設(shè)計(jì)...................................................................................................................62第八章材料、設(shè)備資料..............................................................................................................62

一、鋼板和鋁板的厚度和重量ASHRAE...................................................................................62二、角鋼和角鋁的規(guī)格和重量ASHRAE...................................................................................62三、計(jì)算單位換算........................................................................................................................63四、常用液體的密度(單位:103千克/米3,未注明者為常溫下).....................................64五、空氣調(diào)節(jié)常用計(jì)算公式........................................................................................................65六、鋼材理論重量計(jì)算................................................................................................................67七、專業(yè)英語(yǔ)................................................................................................................................68

第九章耗電量、機(jī)房面積.........................................................................................................81

1、水源熱泵系統(tǒng)設(shè)備耗電量比例..............................................................................................812、醫(yī)院耗電量比例TRANE........................................................................................................813、各種系統(tǒng)分項(xiàng)造價(jià)占總造價(jià)的百分率%(近似)..............................................................814、冷水機(jī)組和附屬設(shè)備估算(△t=5℃)................................................................................815、空調(diào)面積占建筑面積比例......................................................................................................826、空調(diào)機(jī)房建筑面積概算指標(biāo)..................................................................................................827、空調(diào)設(shè)備所占的建筑面積百分率%.......................................................................................838、設(shè)備層布原則:..................................................................................................................83

第十章參考實(shí)例............................................................................................................................84第十一章暖通空調(diào)中存在的問(wèn)題及解決辦法、圖紙要求............................................84

一、貫徹執(zhí)行暖通設(shè)計(jì)規(guī)范、標(biāo)準(zhǔn)方面存在的問(wèn)題................................................................84

1.1室內(nèi)外空氣計(jì)算參數(shù)不符合規(guī)范要求.......................................................................84

1.2供暖熱負(fù)荷計(jì)算有漏項(xiàng)和錯(cuò)項(xiàng)...........................................................................................841.3衛(wèi)生間散熱器型式選擇不妥..............................................................................................841.4樓梯間散熱器立、支管未單獨(dú)配....................................................................................851.5供暖管道敷設(shè)坡度不符合規(guī)范要求....................................................................................851.6廚房操作間通風(fēng)存在問(wèn)題..................................................................................................851.7膨脹水箱與熱(冷)水系統(tǒng)的連接不符合規(guī)范要求...............................................................851.8通風(fēng)空調(diào)系統(tǒng)防火閥的設(shè)不符合規(guī)范要求......................................................................851.9防煙樓梯間前室送風(fēng)口風(fēng)量的確定有問(wèn)題.........................................................................851.10誤將防煙分區(qū)排風(fēng)量的計(jì)算混同于排煙風(fēng)機(jī)風(fēng)量的計(jì)算..................................................861.11高層建筑排煙系統(tǒng)排煙口選型不當(dāng)..................................................................................86

二、在工程設(shè)計(jì)中存在的問(wèn)題....................................................................................................86

2.1供暖入口設(shè)過(guò)多............................................................................................................862.2供暖系統(tǒng)設(shè)計(jì)不合理.........................................................................................................862.32.42.52.6

排風(fēng)系統(tǒng)設(shè)計(jì)不合理.........................................................................................................87空調(diào)系統(tǒng)的選擇不合理.....................................................................................................87廁所采用風(fēng)機(jī)盤管時(shí)未加新風(fēng)...........................................................................................87平衡閥的設(shè)與口徑選擇存在問(wèn)題....................................................................................87

2.7系統(tǒng)分區(qū)不當(dāng)造成失敗.......................................................................................................872.8、雙風(fēng)機(jī)系統(tǒng)設(shè)計(jì)問(wèn)題.........................................................................................................88

第3頁(yè)共95頁(yè)2.9送回風(fēng)管布不好............................................................................................................893.0排氣系統(tǒng)設(shè)計(jì)諸問(wèn)題..........................................................................................................90

三、設(shè)計(jì)圖紙方面存在的問(wèn)題....................................................................................................91

3.1設(shè)計(jì)說(shuō)明內(nèi)容不完整.........................................................................................................913.2平面圖深度不夠,有些應(yīng)該繪制的內(nèi)容遺漏......................................................................913.3系統(tǒng)圖深度不夠................................................................................................................923.4鍋爐房設(shè)計(jì)過(guò)于簡(jiǎn)化.........................................................................................................923.5計(jì)算書(shū)內(nèi)容不全甚至全部空白...........................................................................................923.6暖通空調(diào)設(shè)備未編號(hào)列表表示,圖畫(huà)繁雜不清..................................................................923.7平面圖、剖面圖、系統(tǒng)圖不一致.......................................................................................923.8設(shè)計(jì)圖紙與計(jì)算書(shū)不一致..................................................................................................92

四、問(wèn)題原因及克服方法............................................................................................................93五、施工圖設(shè)計(jì)深度要求............................................................................................................93

設(shè)計(jì)說(shuō)明、施工說(shuō)明、圖例和設(shè)備表.........................................................................................93設(shè)備平面圖...............................................................................................................................93剖面圖......................................................................................................................................94通風(fēng)、空調(diào)、制冷機(jī)房平面圖...................................................................................................94通風(fēng)、空調(diào)、制冷機(jī)房剖面圖...................................................................................................94暖通設(shè)計(jì)中的系統(tǒng)圖、立管圖...................................................................................................94詳圖..........................................................................................................................................94計(jì)算書(shū)(供內(nèi)部使用,備查)...................................................................................................94

第一章設(shè)計(jì)參考規(guī)范及標(biāo)準(zhǔn)

中央空調(diào)主要參考以下的規(guī)范及標(biāo)準(zhǔn):

一、通用設(shè)計(jì)規(guī)范:

1.《采曖通風(fēng)及空氣調(diào)節(jié)設(shè)計(jì)規(guī)范》(GBJI19-87)2.《采暖通風(fēng)及至氣調(diào)節(jié)制圖標(biāo)準(zhǔn)》(GBJ114-88)3.《建筑設(shè)計(jì)防火現(xiàn)范》(GBJ116-87)

4、《高層民用建筑設(shè)計(jì)防火現(xiàn)他》(GBJ0045-95)

5.《民用建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)(采暖居住建筑部分)》(JGJ26-95)

二、專用設(shè)計(jì)規(guī)范:

1、《宿舍建筑設(shè)計(jì)規(guī)范》(JGJ36-87)2、《住宅設(shè)計(jì)規(guī)范》(GB50096-99)3.《辦公建筑設(shè)計(jì)規(guī)范》(JG67-89)4、〈旅館建筑設(shè)計(jì)規(guī)范〉(JGJ67-89)

5.《旅游旅館建筑熱土與空氣調(diào)節(jié)節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)》(GB50189-93)

第4頁(yè)共95頁(yè)6、其它專用設(shè)計(jì)規(guī)范

三、專用設(shè)計(jì)標(biāo)準(zhǔn)圖集:

1.《暖通空調(diào)標(biāo)準(zhǔn)圖集》

2.《暖通空調(diào)設(shè)計(jì)選用手冊(cè)》(上、下冊(cè))3、其它有關(guān)標(biāo)準(zhǔn)

第二章設(shè)計(jì)參數(shù)

一、商業(yè)和公共建筑物的空調(diào)設(shè)計(jì)參數(shù)ASHRAE

室內(nèi)設(shè)計(jì)參數(shù)循環(huán)空建筑物夏季冬季m/s1/h溫度℃相對(duì)濕度溫度℃相對(duì)濕度室內(nèi)空氣流速最小新風(fēng)氣1/s每人空氣過(guò)噪聲NC濾器效年能耗MJ/m率%咖啡室264021~2320~300.25(1.8m)12~15540~50>35570~4500餐廳飲食娛樂(lè)酒吧中心23~2655~6021~2320~300.13~0.158~122.535~40>35570~570023~2650~6021~2320~300.15(1.8m)15~20535~50>35570~4500夜總會(huì)23~2650~6021~2320~3035230~2800廚房29~31-21~23-0.15~0.2512~15全新風(fēng)40~5010~151140~4500辦公樓10I/sm)23~2640~5021~2320~300.23(4~4~100.13~2.5(0.031.3l/sm)~30~4535~60280~340035~60圖書(shū)館、博檔案室物館個(gè)別考慮電訊電話中心電報(bào)22~2640~5021~2640~500.13~0.158~20560>851700~570023~2645~5521~2340~500.13~0.158~20540~5085570~1700電視臺(tái)23~2645~5523~2630~40351140~2300車房26~36-4~13-0.15~0.384~67.535~5010~15230~2300空港大樓運(yùn)輸中心海港大23~2650~60樓21~2320~3023~2650~6021~2320~300.13~8~122.535~50>351140~17000.15(1.8m)0.13~8~122.535~5010~15280~11400.15(1.8m)0.13公車站23~2650~6021~2320~30~8~122.535~50351700~28000.15(1.8m)倉(cāng)庫(kù)個(gè)別考慮-1~4m)2.5(0.05l/s7510~35230~4000二、舒適空調(diào)之室內(nèi)設(shè)計(jì)參數(shù)日本

夏季人體活動(dòng)房間用途Clo等效溫度C。冬季運(yùn)行控制條件(冬-夏)溫度C濕度%Clo。等效溫度C。溫度C。濕度%Clo等效溫度C。溫度。C濕度%會(huì)場(chǎng)、宴會(huì)靜坐、輕度廳、禮堂、活動(dòng)劇院0.6~250.924~2550~700.8~22122~2430~501.0~22~250.622~2530~70辦公室、銀坐、輕度行、旅館、0.2~活動(dòng)餐廳、學(xué)校、0.4住宅2827~2850~701.21.0~1818~2030~500.21.2~18~2818~2830~70百貨公司、0.2~中等活動(dòng)商店、快餐、0.4打字16.525~2650~701.0~16.51.2第6頁(yè)共95頁(yè)16.5~30~5018.51.2~0.216.5~2616.5~30~70體育館、展0.2~觀覽場(chǎng)所覽館0.41527~2850~701.1~151.315~1830~501.3~15~180.215`2830~70三、新風(fēng)量

1、每人的新風(fēng)標(biāo)準(zhǔn)ASHRAE

風(fēng)量1/s應(yīng)用場(chǎng)所吸煙程度推薦一般辦公室個(gè)人個(gè)人少許無(wú)頗重71214單位地板面積1/sm2最小5712-1.31.3會(huì)議室銀行經(jīng)紀(jì)董事室極重偶然極重極重245242414414146.0---理發(fā)室美容室、藥室試驗(yàn)室吧臺(tái)頗重偶然少許重7591454712----公寓豪華少許一般少許9141454471212433-1.71.7-0.3-飯店房間零售店百貨公司小攤重?zé)o無(wú)無(wú)餐廳自助式餐室頗重頗重6756--廚房在餐廳在住宅------201*醫(yī)院手術(shù)室特別房無(wú)無(wú)全新風(fēng)14第7頁(yè)共95頁(yè)

全新風(fēng)12100.病房無(wú)97-無(wú)戲院少許4735--工廠走廊廁所(排風(fēng))車庫(kù)無(wú)---5---4----1.3105

2、最小新風(fēng)量和推薦新風(fēng)量UK

推薦1/s最小1/s面積m2每人所占地板不吸煙吸煙3691211.37.15.24.017.010.77.86.022.614.210.48.03、各類建筑物的換氣次數(shù)UK

建筑物換氣次數(shù)h-1圖書(shū)館書(shū)架房圖書(shū)館公共場(chǎng)所辦公室、試驗(yàn)室銀行大廳、停車場(chǎng)、浴室電影院、戲院衛(wèi)生間(排風(fēng))餐廳修車場(chǎng)(排風(fēng))舞廳宴會(huì)廳、洗衣店、廚房洗滌(排風(fēng))鍋爐房、發(fā)電機(jī)室廚房(排風(fēng))1--23--44--666--106--88--121010--1210--15153020--60第8頁(yè)共95頁(yè)4、各場(chǎng)所每小時(shí)換氣次數(shù)

場(chǎng)所種類廚房寢室一般家庭客廳廁所浴室餐廳廚房旅館及大飯店大食堂廁所浴室飲食室飲食店廚房宴會(huì)室禮堂學(xué)校體育館廁所教室次數(shù)場(chǎng)所1566108101581086201*68126有害氣體塵埃發(fā)出地方20以上工場(chǎng)一般建筑暗室病院戲院種類觀覽室放映室等候室診療室手術(shù)室消毒室一般作業(yè)室涂裝室事務(wù)室會(huì)議室沖洗片室公共廁所次數(shù)12201*615126206121020依人數(shù)計(jì)算換氣量

換氣對(duì)象男人婦女小孩牛馬

換氣量m/min1.411.160.753.8334、每人的新風(fēng)標(biāo)準(zhǔn)UK

逗留者密度每人所占吸煙程度地板面積m2風(fēng)量1/s面積風(fēng)量1/sm2單位地板換氣次數(shù)h-1無(wú)稀≥8少許重69121.01.41.81.01.52.0第9頁(yè)共95頁(yè)密3--7無(wú)少許重912152.83.74.63.04.05.0無(wú)擠≤2少許重1215186.78.310.07.09.011.05、考慮節(jié)能的基本新風(fēng)量(1/s人)(日本)

房間主要負(fù)荷人體活動(dòng)房間用途無(wú)吸煙有吸煙基本風(fēng)量1/s近于安靜人體為主要負(fù)荷輕活動(dòng)中等活動(dòng)重活動(dòng)打字室、中等勞動(dòng)體育館、重勞動(dòng)車間辦公室、教室、走廊、大廳、會(huì)議室、百貨店、餐廳、觀眾廳、輕工作舞廳、游戲場(chǎng)、8.510153030304050606090其它美容室、理發(fā)室、吸煙室-6、辦公室環(huán)境衛(wèi)生標(biāo)準(zhǔn)日本

溫度℃相對(duì)濕度%夏季冬季流速m/smg/m含有率PPM含有率PPM室內(nèi)空氣浮游粉塵量二氧化碳一氧化碳22-2817-2240--700.05--0.02<0.15<102星級(jí)以下≥22餐廳、宴會(huì)廳、多功能廳3~5星級(jí)≥302星級(jí)以下≥20辦公樓≥30住宅≥30中小學(xué)教室小學(xué)≥11初中≥14高中≥17文化娛樂(lè)場(chǎng)所影劇院、音樂(lè)廳、錄像廳≥20游藝廳、舞廳≥30酒吧、茶座、咖啡廳≥10圖書(shū)館、博物館、美術(shù)館≥30展覽館≥20體育館觀眾席≥20商場(chǎng)(店)、書(shū)店設(shè)有空調(diào)裝置≥20飯店(餐廳)≥20公共交通工具旅客列車車廂≥20輪船客艙≥20飛機(jī)客艙≥25公共交通等候室侯車室、侯船室(二等以上)第11頁(yè)共95頁(yè)

≥侯機(jī)室≥20醫(yī)院侯診室≥30《采暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范》(報(bào)批稿)第3.1.9條:

(強(qiáng)制性條文)建筑物室內(nèi)人員所需最小新風(fēng)量,應(yīng)符合以下規(guī)定:①民用建筑人員所需最小新風(fēng)量按現(xiàn)行有關(guān)衛(wèi)生標(biāo)準(zhǔn)確定;②工業(yè)建筑應(yīng)保證每人少于30m/h的新風(fēng)量。

表3.1.9民用建筑主要房間人員所需的最小新風(fēng)量參考值〔m/(hP)〕

房間類型新風(fēng)量參考依據(jù)3

3

旅游旅館、飯店客房3~5星級(jí)≥30GB9663-19962星級(jí)以下≥20GB9663-1996餐廳、宴會(huì)廳、多功能廳3~5星級(jí)≥30GB9663-19962星級(jí)以下≥20GB9663-1996會(huì)議室、辦公室、接待室3~5星級(jí)≥50GB9663-19962星級(jí)以下≥30GB9663-1996醫(yī)院病房大≥35GB9663-1996小≥50GB9671-1996診室≥25GB9671-1996手術(shù)室≥60GB9671-1996辦公樓辦公室(無(wú)煙)高級(jí)35~50室內(nèi)空氣質(zhì)量標(biāo)準(zhǔn)一般25~30室內(nèi)空氣質(zhì)量標(biāo)準(zhǔn)會(huì)議室(無(wú)煙)30~50室內(nèi)空氣質(zhì)量標(biāo)準(zhǔn)學(xué)校教室小學(xué)第12頁(yè)共95頁(yè)

≥11GB/T17226-19初中≥14GB/T17226-1998高中≥17GB/T17226-1998文體建筑影劇院、音樂(lè)廳觀眾廳≥20GB9664-1996體育館觀眾廳≥20GB9668-1996室內(nèi)游泳池10~15GB9668-1996展覽館、博物館展廳、觀眾廳10~15GB9669-1996圖書(shū)館閱覽室≥15GB9669-1996商店10~20GB9670-1996注:大學(xué)教室可參照會(huì)議室標(biāo)準(zhǔn)

第三章空調(diào)負(fù)荷計(jì)算

一、不同窗面積下,冷負(fù)荷之分布%

玻璃窗所占面積%人體、燈光、辦公室設(shè)備窗戶新鮮空氣墻253626233125027431721175225314110二、負(fù)荷指標(biāo)(估算)(僅供參考)

建筑類型住宅、公寓、標(biāo)準(zhǔn)客房西餐廳中餐廳火鍋城、燒烤冷負(fù)荷W/m2114-138200-286257-438465-698第13頁(yè)共95頁(yè)

(Cal/m2)(98-118)(170-246)(220-376)(400-600)小商店大商場(chǎng)、百貨大樓理發(fā)、美容會(huì)議室辦公室中庭、接待圖書(shū)館展廳、陳列室劇場(chǎng)計(jì)算機(jī)房、網(wǎng)吧有潔凈要求的廠房、手術(shù)室等175-267250-400150-225210-300128-170112-15090-125130-201*80-350230-410300-500(150-230)(215-344)(129-193)(180-258)(110-146)(97-129)(77-108)(112-172)(154-310)(200-350)(258-430)三、空調(diào)冷負(fù)荷法估算冷指標(biāo)?照{(diào)冷負(fù)荷法估算冷指標(biāo)(W/m2空調(diào)面積)見(jiàn)下表

建筑類型及序號(hào)房間名稱1234567客房宴會(huì)廳小會(huì)議室大會(huì)議室健身房保齡球舞廳科研辦公樓商場(chǎng)平方米/人101.2531.5535負(fù)荷60306040352040負(fù)荷71344388879728負(fù)荷20304040202040空調(diào)建筑面積建筑人體照明新風(fēng)量W/m250252525603320新風(fēng)總負(fù)荷負(fù)荷271909219013011943114360235358272256151第14頁(yè)共95頁(yè)89101112131415161718192021222324底層二層三層及三層以上圖書(shū)館閱覽室展覽廳陳列室會(huì)堂報(bào)告廳公寓住宅硬劇院觀眾廳休息廳化妝室體育館比賽館休息廳貴賓廳醫(yī)院高級(jí)病房一般手術(shù)室潔凈手術(shù)室X光CTB超1.01.223535401601288040404012121213010465365307225105014302527121458312025681772103570581440202550136542691580.5243070402286435152050840201*4216554473701802.5583570586527.517402030154050658668205203173第15頁(yè)共95頁(yè)

110150300125餐館300注:本表為最大負(fù)荷,在求建筑總冷負(fù)荷時(shí),應(yīng)考慮空調(diào)房間同時(shí)使用系數(shù)0.7-0.9

四、按建筑面積冷指標(biāo)進(jìn)行估算建筑面積冷指標(biāo)

冷負(fù)荷指標(biāo)建筑名稱W/m建筑面積100-135體育館200-350(按人員座位數(shù))計(jì)算機(jī)房數(shù)據(jù)處理190-380320-400126-1602冷負(fù)荷指標(biāo)建筑名稱W/m建筑面積旅館辦公樓圖書(shū)館醫(yī)院80-9085-10035-4080-902105-125商店?duì)I業(yè)廳設(shè)空調(diào)時(shí),200-250按營(yíng)業(yè)廳面積劇院200-300(按觀眾廳面積)會(huì)堂180-225注:l、上述指標(biāo)為總建筑面積的冷負(fù)荷指標(biāo):建筑面積的總建筑面積小于5000平米時(shí),取上限;大于

l0000平米,取下限值。

2、按上述指標(biāo)確定的冷負(fù)荷,即是制冷機(jī)的容量,不必再加系數(shù)。

3、由于地區(qū)差異較大,上述指標(biāo)以北京地區(qū)為準(zhǔn)。南方地區(qū)可按上限采取。

熱負(fù)荷估算

(l)按建筑面積熱指標(biāo)進(jìn)行估算

注:總建筑面積、大外圍結(jié)構(gòu)熱工性能好、窗戶面積小,采用較小的指標(biāo);反之采用較大的指標(biāo)。(2)窗墻比公式法:

q=(7a+1.7)W/F(tn-tw)W/m2;說(shuō)明:q建筑物的供熱指標(biāo),W/m2。

a外窗面積與外墻面積(包括窗之比);W一外墻總面積(包括窗),m2F一總建筑面積,m2tn一室內(nèi)供暖設(shè)計(jì)溫度,℃tw一室外供暖設(shè)計(jì)溫度,℃

第16頁(yè)共95頁(yè)五、建筑物冷負(fù)荷概算指標(biāo)香港

冷負(fù)荷W/m2建筑物顯冷負(fù)荷中部區(qū)辦公室周邊個(gè)人辦公室會(huì)議室教室學(xué)校圖書(shū)館自動(dòng)餐廳高層、南向高層、北向6511016018513013015011080110150951105013011015013011011011011013016080110總冷負(fù)荷95160240270190190260160130260230150380150201*00250225201*101601602603201*0160逗留者m2/人照明W/m2送風(fēng)量L/sm210101532.561.51010110106101041.52332.552210106060606040303020202050402030405040604030403015171515568999101091210888101012108101010101278公寓戲院、大會(huì)堂試驗(yàn)室圖書(shū)館、博物館手術(shù)室公共場(chǎng)所醫(yī)院衛(wèi)生所、診所理發(fā)室、美容院地下中間層上層藥店零售店精品店酒吧餐廳房間公共場(chǎng)所百貨公司飯店第17頁(yè)共95頁(yè)工廠裝配室輕工業(yè)會(huì)客室一般比賽公開(kāi)比賽1501601601101102602602402202403.515653453020408091081212室內(nèi)場(chǎng)所六、各類建筑物鍋爐負(fù)荷估算W/m3℃

建筑物W/m3℃0.6--1.20.5--0.90.5--1.11.1--2.01.5--3.00.5--1.2辦公室劇院觀眾席百貨商店旅館紡織廠七、熱損失概算W/m℃

建筑物混凝土建筑(全部)混凝土建筑(最上層)混凝土建筑(中間各層)木結(jié)構(gòu)建筑(全部)木結(jié)構(gòu)建筑(各房間)W/m℃一每m3房間容積,室內(nèi)外溫差1℃時(shí)的熱量W。

W/m℃0.8--1.11.3--2.10.8--1.31.1--1.31.3--1.7八、冷庫(kù)冷負(fù)荷概算指標(biāo)

KW/100m3冷庫(kù)容積m33℃100mm隔熱14--3031--6061--1201*1--2203.73.02.42.1第18頁(yè)共95頁(yè)

-10℃150mm隔熱3.93.12.52.2-18℃200mm隔熱3.83.12.52.221--440441--900901--14001.81.51.21.91.61.51.91.61.4第四章風(fēng)管系統(tǒng)設(shè)計(jì)

一、通風(fēng)管道流量阻力表1、縮伸軟管摩擦阻力表

圓形風(fēng)管Φ150Φ200Φ250Φ300v=2m/s127/0.43226/0.32353/0.26509/0.21v=3m/s190/0.98339/0.73530/0.558764/0.95v=4m/s254/1.8452/1.30707/1.041018/1.62v=5m/s318/3.23565/2.03883/1.621273/2.44v=6m/s381/4.46678/2.921060/2.331521/3.582、鍍鋅板風(fēng)管摩擦阻力表

矩型風(fēng)管mmv=2m/s104/0.61138/0.51184/0.42173/0.46230/0.36216/0.41288/0.32360/0.27風(fēng)量(m/h)/摩擦阻力(Pa)v=3m/s156/1.27207/1.07277/0.78259/0.95346/0.77324/0.87432/0.69540/0.58v=4m/s207/2.15277/1.8369/1.49346/1.62461/1.3432/1.47576/1.17720/0.99v=5m/s259/3.25346/2.75461/2.26432/2.45576/1.79540/2.23720/1.77900/1.50v=6m/s311/14.57415/3.86553/3.17734/3.44691/2.78648/864/2.481080/2.113120x1201*0x1201*0x160200x120200x160250x120250x160250x200第19頁(yè)共95頁(yè)320x120320x160320x201*20x250400x120400x160400x201*00x250500x160500x201*00x250500x320500x400630x160630x201*30x250630x320630x400630x500800x160800x201*00x250269/0.38369/0.29461/0.25576/0.21336/0.35461/0.27576/0.22720/0.19576/0.25720/0.21900/0.171152/0.141440/0.12726/0.22907/0.191134/0.161452/0.131814/0.112268/0.1922/0.201*52/0.181440/0.14403/0.79553/0.61691/0.51864/0.43504/0.74691/0.56864/0.461080/0.38864/0.521080/0.421350/0.351728/0.282160/0.251089/0.481361/0.391701/0.322177/0.262722/0.223402/0.191382/0.421728/0.372160/0.3537/1.34737/1.049221/0.871152/0.74673/1.25922/0.951152/0.781440/0.661152/0.891440/0.731800/0.602304/0.492880/0.421452/0.841814/0.672268/0.552903/0.443629/0.374536/0.311843/0.672304/0.632880/0.51672/2.03922/1.581152/1.311440/1.12841/1.901152/1.451440/1.201*00/1.001440/1.341800/1.12250/0.902880/0.753600/0.641814/1.122268/1.022835/0.833629/0.674536/0.565670/0.482304/1.022880/0.953600/0.77806/2.861106/2.221382/1.851728/1.571009/2.671382/2.031728/1.682160/1.401728/1.892160/1.542700/1.283456/1.054320/0.892177/1.982722/1.433402/0.194355/0.945443/0.796804/0.682765/2.153456/1.344320/1.08第20頁(yè)共95頁(yè)800x3201*00x201*000x2501000x320圓形風(fēng)管Φ100Φ140Φ200Φ250Φ360Φ400Φ500說(shuō)明

1843/0.11440/0.161800/0.132304/0.11v=2m/s55/0.76109/0.49224/0.313.49/0.24727/0.15898/0.131405/0.12765/0.232160/0.352700/0.283456/0.23v=3m/s83/1.58164/1.03336/0.66524/0.51090/0.321347/0.282108/0.213686/0.402880/0.603600/0.484608/0.37v=4m/s111/2.68219/1.75448/1.12698/0.851454/0.541796/0.472811/0.364608/0.603600/0.904500/0.725760/0.57v=5m/s139/4.05273/2.64560/1.69873/1.281817/0.822245/0.723513/0.555530/0.854320/1.305400/1.026912/0.80v=6m/s166/5.69328/3.72672/2.381048/1.802180/1.152694/1.014216/0.77(1).軟管采用荷蘭數(shù)據(jù)時(shí),上述數(shù)據(jù)乘以下系數(shù):

Φ150x2;Φ200x1.8;Φ250x1.5;Φ300x1.3(2).局部摩擦阻力:

ΔP(Pa)v=2m/s15.923.829.4v=3m/s35.753.566.0v=4m/s63.495.1117.3v=5m/s99.1148.7183.2v=6m/s142.7214.1263.9散流器喉徑(mm)200x201*00x300400x400(3)與散流器的摩擦阻力:

第21頁(yè)共95頁(yè)接管規(guī)格(mm)v=2m/s2.46.410.810.1v=3m/s5.314.3222.322.7ΔP(Pa)v=4m/s9.425.528.840.4v=5m/s14.739.841.363.1v=6m/s21.257.354.190.8鍍鋅管200x200鍍鋅管400x400軟管Φ150軟管Φ350(4).保持風(fēng)速必須的動(dòng)壓:

當(dāng)v=2m/s時(shí),ΔP=2.4Pa;當(dāng)v=3m/s時(shí),ΔP=5.4Pa當(dāng)v=4m/s時(shí),ΔP=9.6Pa;當(dāng)v=5m/s時(shí),ΔP=15Pa當(dāng)v=6m/s時(shí),ΔP=21Pa

2(5).其他局部阻力的計(jì)算按下式:V

ΔP=ζ─γ2g

二、室內(nèi)送回風(fēng)口尺寸表1、風(fēng)口風(fēng)量冷量對(duì)應(yīng)表

冷量RT1.01.52.02.53.03.54.0kw3.55.378.710.512.214風(fēng)量m/h送風(fēng)口mm回風(fēng)口mm75080010001450160018001950700x150700x150900x1501000x201*100x201*250x200/1000x2501000x250800x150800x1501000x150/800x201*200x201*300x201*500x200/1200x2501300x250第22頁(yè)共95頁(yè)5.017.5830001600x250/1360x3002、不同送風(fēng)方式的風(fēng)量指標(biāo)和室內(nèi)平均流速ASHRAE

單位地板面積的送風(fēng)量l/sm3--64--105--155--255-502送風(fēng)方式工作區(qū)平均流速m/s0.13--0.180.10--0.180.10--0.180.10--0.250.05--0.15換氣次數(shù)h-1側(cè)送百葉風(fēng)口條形風(fēng)口局部孔板送風(fēng)頂棚散流器頂棚孔板送風(fēng)712183060三、室內(nèi)風(fēng)管風(fēng)速選擇表

1、低速風(fēng)管系統(tǒng)的推薦和最大流速m/s

住宅應(yīng)用場(chǎng)所推薦室外空氣入口空氣過(guò)濾器加熱排管冷卻排管淋水室風(fēng)機(jī)出口主風(fēng)管支風(fēng)管(水平)支風(fēng)管(垂直)2.51.32.32.32.56.04.03.02.5最大4.01.52.52.32.58.56.05.04.0推薦2.51.52.52.52.59.06.04.03.5最大4.51.83.02.52.511.08.06.56.0推薦2.51.83.03.02.510.09.05.04.0最大8.01.83.53.02.514.011.09.08.0公共建筑工廠2、低速風(fēng)管系統(tǒng)的最大允許速m/s

以摩擦阻力控制送風(fēng)主管5.07.510.06.5回風(fēng)主管4.06.57.55.5送風(fēng)支管3.06.08.05.0回風(fēng)支管3.05.06.14.0應(yīng)用場(chǎng)所以噪聲控制主風(fēng)管住宅公寓、飯店房間辦公室、圖書(shū)館大禮堂、戲院3.05.06.04.0第23頁(yè)共95頁(yè)銀行、高級(jí)餐廳百貨店、自助餐廳工廠7.59.012.510.012.015.07.57.59.08.08.011.06.06.07.53、通風(fēng)系統(tǒng)之流速m/s

系統(tǒng)送風(fēng)、最大流速低速送風(fēng)、一般流速回風(fēng)、最大流速回風(fēng)、一般流速高速、一般

室內(nèi)允許噪聲dB(A)25-3535-50主管風(fēng)速m/s3-44-6支管風(fēng)速m/s≤22-3商業(yè)136--11107.5--913工業(yè)1311--13139--1313--25注:民用住宅≤35dB(A),商務(wù)辦公≤45dB(A)。

四、室內(nèi)風(fēng)口風(fēng)速選擇表1、送風(fēng)口風(fēng)速

臥室起居1.5-2m/s(風(fēng)口在上部時(shí))2-3m/s(風(fēng)口在上部時(shí))3m/s(風(fēng)口距地≤2.5m)辦公室4m/s(風(fēng)口距地≤4.5m)商場(chǎng)、娛樂(lè)3-5m/s第24頁(yè)共95頁(yè)2、以噪音標(biāo)準(zhǔn)控制的允許送風(fēng)流速m/s

應(yīng)用場(chǎng)所圖書(shū)館、廣播室住宅、公寓、私人辦公室、醫(yī)院房間銀行、戲院、教室、一般辦公室、商店、餐廳工廠、百貨公司、廚房流速m/s1.75--2.52.5--4.04.0--5.05.0--7.53、推薦的送風(fēng)口流速m/s

應(yīng)用場(chǎng)所流速m/s1.5--2.52.5--3.52.5--3.82.5--4.05.0--6.05.07.510.0播音室戲院住宅、公寓、飯店房間、教室一般辦公室電影院百貨店、上層百貨店、地下4、送風(fēng)口之最大允許流速m/s

應(yīng)用場(chǎng)所廣播室醫(yī)院療房飯店房間、會(huì)客室百貨公司、劇場(chǎng)教室、圖書(shū)館、辦公室盤形送風(fēng)口3.0--3.54.0--4.54.0--4.56.0--7.55.0--6.0頂棚送風(fēng)口4.0--4.54.5--5.05.0--6.06.2--7.56.0--7.5側(cè)送風(fēng)口2.52.5--3.02.5--4.05.0--7.03.5--4.55、回風(fēng)口風(fēng)速

房間凈高3.5-43-3.52.5-3風(fēng)口位置上部上部上部第25頁(yè)共95頁(yè)

風(fēng)速3-4m/s2-3m/s1.5-2m/s人不常停留處人常停留處走廊回風(fēng)下部下部下部3m/s1.5-2m/s1-1.5m/s6、回風(fēng)格柵的推薦流速m/s

位置流速m/s近座位2--3逗留區(qū)以上3--4門下部4門上部3工業(yè)用≥47、百葉窗的推薦流速m/s

位置流速m/s新風(fēng)2.5--4回風(fēng)4--6減溫器正面2--4減溫器旁通7.5--12加熱器旁通5--7.58、逗留區(qū)流速與人體感覺(jué)的關(guān)系

流速m/s--0--0.080.1270.127--0.250.380.380.38--1.52不舒適,停滯空氣的感覺(jué)理想,舒適基本舒適不舒適,可以吹動(dòng)薄紙對(duì)站立者為舒適感之上限用于工廠和局部空間人體感覺(jué)9、頂棚散流器送風(fēng)量

送風(fēng)流速m/s尺寸mm1.01.52.02.53.755.0250*2505070951201*5235300*30070100135170255340350*35090140185230350465第26頁(yè)共95頁(yè)400*4001201*0240295440590500*500190280380470710945600*60027041054568010201*6010、側(cè)送風(fēng)口送風(fēng)量

送風(fēng)口流速m/s送風(fēng)口尺寸mm1.52.02.53.755.0250*1003040507095300*10035455585115400*100456075115150500*100557595145190600*1007090115170230750*10085115145215285900*100100135170255340250*150455570105145300*150507085130170400*1507090115170230500*15085115145215285600*150100135170255340750*150130170215320430第27頁(yè)共95頁(yè)900*150155205255385515400*201*01201*0230305500*201*15150190285380600*201*35180230340455750*201*70230285430570900*201*05275340415685400*250115150190285380500*250145190240355475600*250170230285430570750*250215285355535715900*2502553404306408551000*505575951451901000*75851151452152851000*1001151501902853801000*1251451902403554751000*1501702302854305701000*175201*653305006651000*201*30305380570760第28頁(yè)共95頁(yè)五、通風(fēng)系統(tǒng)設(shè)計(jì)1、送風(fēng)口布間距

辦公室商場(chǎng)、娛樂(lè)回風(fēng)口應(yīng)根據(jù)具體情況布置

一般原則:(1)人不經(jīng)常停留的地方;(2)房間的邊和角;(3)有利于氣流的組織。

2.5-3.5m4-6m2、標(biāo)準(zhǔn)型號(hào)風(fēng)盤所接散流器的尺寸表-辦公室

風(fēng)盤型號(hào)FP3.556.381012.5162025注:辦公室推薦送風(fēng)口流速:2.5-4.0m/s

風(fēng)機(jī)盤管接風(fēng)管的風(fēng)速:通常為1.52.0m/s之間,不能大于2.5m/s,否則會(huì)將冷凝水帶出來(lái)。

風(fēng)量m3/h35050063080010001250160025002500方散尺寸mm200*201*00*201*50*250250*250300*300300*300350*350450*450450*4503、散流器布

散流器平送時(shí),宜按對(duì)稱布置或者梅花型布置,散流器中心與側(cè)墻的距離不宜小于1000mm;圓形或方形散流器布置時(shí),其相應(yīng)送風(fēng)范圍(面積)的長(zhǎng)寬比不宜大于1:1.5,送風(fēng)水平射程與垂直射程(平頂至工作區(qū)上邊界的距離)的比值,宜保持在0.5~1.5之間。實(shí)際上這要看裝飾要求而定,如250*250的散流器,間距一般在3.5米左右,320*320在4.2米左右。

第29頁(yè)共95頁(yè)4、空調(diào)房間允許最大送風(fēng)溫差℃

下列房間高度m送風(fēng)方式2側(cè)送、大風(fēng)量側(cè)送、小風(fēng)量頂棚散流器舒適性空調(diào)的送風(fēng)溫差

送風(fēng)高度H小于等于5m,送風(fēng)溫差小于等于10度;送風(fēng)高度H大于5m,送風(fēng)溫差小于等于15度。

為防止出風(fēng)口結(jié)露,應(yīng)使送風(fēng)干球溫度高于室內(nèi)空氣的露點(diǎn)溫度2-3度。

6.59.09.538.311164101317512151861417185、工藝性空氣調(diào)節(jié)空調(diào)房間允許最大送風(fēng)溫差.

室溫允許波動(dòng)范圍(C)>±1.0±1.0±2.0±1.0~0.2送風(fēng)溫差(C)風(fēng)量帶來(lái)了困難,通常同樣的廚房,不同的人進(jìn)行設(shè)計(jì),其結(jié)果往往不同,甚至相差懸殊,但是依據(jù)技術(shù)措施,又能各自找到根據(jù)。因此,廚房的通風(fēng)設(shè)計(jì)形成了,因人而異,無(wú)統(tǒng)一標(biāo)準(zhǔn)的局面,我認(rèn)為之所以會(huì)出現(xiàn)這種現(xiàn)象,與我們常用的《技術(shù)措施》在廚房通風(fēng)量確定上,概念不明確,要求不一致有關(guān),為說(shuō)明問(wèn)題,我們可以結(jié)合常用的建設(shè)部建筑設(shè)計(jì)院《民用建筑暖通空調(diào)設(shè)計(jì)技術(shù)措施》,(下簡(jiǎn)稱《措施一》)和我院編制的《暖通專業(yè)統(tǒng)一技術(shù)措施》(下簡(jiǎn)稱《措施二》)中的有關(guān)規(guī)定,討論一下廚房的通風(fēng)量確定問(wèn)題!洞胧┮弧返4-28條規(guī)定:機(jī)械通風(fēng)的換氣量宜按熱平衡計(jì)算,計(jì)算排風(fēng)量的65%通過(guò)排氣罩或屏幕等排除室外,而由房間的全面換氣排出35%。另外,在第4-26條中,已規(guī)定了排氣罩口的風(fēng)速應(yīng)控制在0.4~0.5m/s!洞胧┒返513條中規(guī)定:設(shè)有空調(diào)系統(tǒng)的廚房其機(jī)械通風(fēng)的換氣量,宜按熱平衡及風(fēng)量平衡計(jì)算,當(dāng)熱平衡計(jì)算確有困難時(shí),可按下述兩種方法中的一種計(jì)算,并以第一種方法,為優(yōu)選方法。1.L1=1800F1(F1為罩口面積)L2=10F2(F2為廚房面積)L=L1+L2(L為總排氣量)2.按60~80次/時(shí)換氣計(jì)算,(廚房面積小于50時(shí)取上限,大于50時(shí)取下限)。廚房排風(fēng)中應(yīng)有相當(dāng)于3~5次/時(shí)換氣次數(shù)的風(fēng)量為全面換氣設(shè)備排出,但不計(jì)入總風(fēng)量。從《措施一》《措施二》的規(guī)定中,我們似乎得到一個(gè)左右廚房通風(fēng)量計(jì)算的一個(gè)概念。那就是,在廚房的排氣罩工作時(shí),還應(yīng)該有其它的排風(fēng)機(jī)在同時(shí)工作,廚房?jī)?nèi)的排風(fēng)不能僅從排氣罩排出,而必須留有其它排風(fēng)出路,并且要有一定的比例關(guān)系,或者占到全部排風(fēng)量的35%或者占到相當(dāng)于3~5次/時(shí)換氣次數(shù)的風(fēng)量。如何保證這樣的比例關(guān)系呢?,我們可以根據(jù)計(jì)算總通風(fēng)量時(shí)可能遇到的幾種情況具體分析設(shè)計(jì)過(guò)程!洞胧┮弧分,指明了其通風(fēng)量是按熱平衡計(jì)算的風(fēng)量,也規(guī)定了,排氣罩口的風(fēng)速應(yīng)控制在0.4~0.5m/s之內(nèi),這里就出現(xiàn)了兩個(gè)計(jì)算風(fēng)量,一個(gè)是按熱平衡法計(jì)算的廚房總換氣量,另一個(gè)是滿足罩口風(fēng)速為0.4~0.5m/s的排氣罩風(fēng)量,前者我們另其為L(zhǎng),后者另其為L(zhǎng)1,這里的問(wèn)題是L和L1,可能存在著各種比例關(guān)系,L1可能小于L,但L1也可能大于L。當(dāng)L1對(duì)具體工程進(jìn)行具體分析,就會(huì)造成設(shè)計(jì)人員理解這些技術(shù)措施上的混亂和應(yīng)用這些技術(shù)措施上的差異,其結(jié)果往往使得廚房的通風(fēng)量,人為地增加,造成通風(fēng)機(jī)過(guò)大、過(guò)多、耗電量增加。相比之下,北京市建筑設(shè)計(jì)研究院的《建筑設(shè)備專業(yè)設(shè)計(jì)技術(shù)措施》有關(guān)規(guī)定,指定的嚴(yán)謹(jǐn)、清晰,本措施的第3627條有如下規(guī)定。1.廚房機(jī)械通風(fēng)的總排風(fēng)量,宜根據(jù)廚房散熱量和送風(fēng)量溫差,按熱平衡計(jì)算。2.當(dāng)計(jì)算排風(fēng)量大于爐灶排氣罩的排風(fēng)量時(shí),多余部分應(yīng)由全面排氣設(shè)備排出;當(dāng)爐灶排氣罩的排風(fēng)量大于計(jì)算排風(fēng)量時(shí),總換氣量按其較大值確定并可另外適當(dāng)設(shè)置全面排風(fēng)設(shè)備,在爐灶排風(fēng)未運(yùn)行時(shí)使用,但不計(jì)入總換氣量。實(shí)際上,我們通常接觸到的工程,很少有能夠按熱平衡法計(jì)算通風(fēng)量的廚房,而失去了這一前提條件,再參照上述的《措施》進(jìn)行設(shè)計(jì),試圖滿足其各種規(guī)定很可能出現(xiàn),因人而異,設(shè)備設(shè)置過(guò)多的現(xiàn)象。我認(rèn)為在不可能進(jìn)行熱平衡計(jì)算的前提下,廚房的通風(fēng)量計(jì)算,按照廚房的使用特點(diǎn),把握兩點(diǎn)即可。1.排氣罩通風(fēng)量。2.平時(shí)通風(fēng)量。排氣罩的排風(fēng)量為了保證灶臺(tái)工作時(shí)油煙不外溢,而必須設(shè)的其通風(fēng)量,按罩口面積、罩口風(fēng)速0.4-0.5m/s計(jì)算。一般而言,廚房爐灶使用的高峰時(shí)間為4-5個(gè)小時(shí),而其余時(shí)間為加工及準(zhǔn)備或衛(wèi)生時(shí)間,這時(shí)不需要太大的通風(fēng)量。因此在排風(fēng)罩排風(fēng)量計(jì)算完后,再考慮一個(gè)平時(shí)通風(fēng)量,可以按換氣次數(shù)3-5次/時(shí)計(jì)算。計(jì)算補(bǔ)風(fēng)時(shí),可以排氣罩的風(fēng)量為依據(jù)。另外對(duì)于過(guò)長(zhǎng)的排氣罩,還可以考慮分設(shè)兩臺(tái)或兩臺(tái)以上的排風(fēng)機(jī)。以適應(yīng)灶臺(tái)工作的多少變化,采用熱平衡法之外的計(jì)算方法確定的風(fēng)量,有可能風(fēng)量不夠,無(wú)法完全消除室內(nèi)的余熱,但可以通過(guò)崗位送風(fēng)進(jìn)行禰補(bǔ),這比無(wú)根據(jù)地人為增大總排風(fēng)量,更容易讓人接受。以上是本人在廚房通風(fēng)量計(jì)算上的一點(diǎn)看法,本人希望通過(guò)對(duì)廚房通風(fēng)量計(jì)算的討論,引起同行人士的重視,進(jìn)而找到更加合理的計(jì)算方法。

6.3廚房通風(fēng)設(shè)計(jì)中的幾個(gè)問(wèn)題

一、概述

廚房通風(fēng)中產(chǎn)生問(wèn)題的主要原因,一方面是由于廚房工藝設(shè)計(jì)專業(yè)與通風(fēng)設(shè)計(jì)專業(yè)之間協(xié)調(diào)不夠,另一方面,由于我國(guó)廚房設(shè)計(jì)缺乏經(jīng)驗(yàn),設(shè)計(jì)不盡合理。二、廚房通風(fēng)量計(jì)算

廚房的通風(fēng)量由兩部分組成,即局部排風(fēng)量和全面排風(fēng)量?jī)刹糠。局部排風(fēng)量應(yīng)選用的灶具和廚房排風(fēng)罩的情況加以確定,全面排風(fēng)量一般按計(jì)算確定。1.通風(fēng)量的計(jì)算

機(jī)械通風(fēng)的換氣量應(yīng)通過(guò)熱平衡計(jì)算求利,其計(jì)算公式:L=Q/0.337(tp-ti)(1)式中,L--必須的通風(fēng)量、m3/h;

tp--室內(nèi)排風(fēng)計(jì)算溫度,可采用下列數(shù)值:夏季35攝氏度,冬季15攝氏度;ti--室內(nèi)通風(fēng)計(jì)算溫度,攝氏度;Q--廚房?jī)?nèi)的總發(fā)熱量(顯熱),W;

Q=Q1+Q2+Q3+Q4(2)

式中,Q1--廚房設(shè)備散熱量,按工藝提供數(shù)據(jù)計(jì)算,如無(wú)資料時(shí),可參考文獻(xiàn);

第32頁(yè)共95頁(yè)Q2--操作人員散熱量,W;Q3--照明燈具散熱量,W;

Q4--室內(nèi)外圍護(hù)結(jié)構(gòu)的冷負(fù)荷,W。2.局部排風(fēng)量

局部排風(fēng)量按排風(fēng)罩面的吸入風(fēng)速計(jì)算,其最小排風(fēng)量為L(zhǎng)=1000PH式中,L--排風(fēng)罩排風(fēng)量,m3/L;

P--罩子的周邊長(zhǎng)(靠墻的邊長(zhǎng)不計(jì)),m;H--罩口至灶面的距離,m。3.廚房通風(fēng)量估算

在總結(jié)工程設(shè)計(jì)及使用的基礎(chǔ)上,設(shè)計(jì)人員可按如下通風(fēng)次數(shù)進(jìn)行估算:中餐廚房n=40-50h-1;西餐廚房n=30-40h-1;

在估算出的通風(fēng)量中,局部排風(fēng)量按65%考慮,全面排風(fēng)量按35%考慮。三、局部排風(fēng)部位及要求

中餐廚房,其烹調(diào)的發(fā)熱量和排煙量一般較大,排風(fēng)量也較大,排氣罩一般選用抽油煙罩。為減輕油煙對(duì)環(huán)境的影響,可選用消洗煙罩。

蒸煮間。此間對(duì)新風(fēng)的要求較低,但排風(fēng)效果一定要好,否則,蒸汽將充滿整個(gè)工作間,影響廚師工作,排氣排出的主要是水蒸氣,可以不采用和凈化裝置,直接排出。

西餐廚房。烹調(diào)量并不很大,但要求設(shè)備多而全,排風(fēng)量要小于中餐廚房。洗碗間。需要較大的排風(fēng)量。四、廚房補(bǔ)風(fēng)的要求

在廚房通風(fēng)中,要補(bǔ)充一定數(shù)量的新風(fēng),送風(fēng)量應(yīng)按排風(fēng)量的80%-90%考慮。

廚房?jī)?nèi)負(fù)壓值不利大于5Pa,因負(fù)壓過(guò)大,爐膛會(huì)倒風(fēng)。因而應(yīng)使送風(fēng)機(jī)與排風(fēng)機(jī)均有調(diào)速的可能?蓪⒀a(bǔ)風(fēng)量的30%作為崗位送風(fēng),送風(fēng)口直接均勻布置排氣罩前側(cè)上方。

廚房送風(fēng)可直接利用室外新風(fēng),僅設(shè)置粗效過(guò)濾器。此外,為改善炊事人員工作環(huán)境,宜按條件設(shè)局部或全面冷卻裝置。廚房用具發(fā)散的熱量與空氣調(diào)節(jié)冷卻負(fù)荷的關(guān)系,可用下式計(jì)算:

第33頁(yè)共95頁(yè)灶具熱源為煤氣的場(chǎng)合:qc=qeF1F2≈0.1qe。(3)

式中qc--廚房空調(diào)冷負(fù)荷,kW;qe--廚房設(shè)備散熱量,kW;F1--設(shè)備同時(shí)使用系數(shù),取0.5;

F2--設(shè)備輸入功率中表面輻射熱的比例,取0.32;F3--排風(fēng)排熱系數(shù),取1.6。灶具熱源為使用電及蒸汽的場(chǎng)合:qc=qeF1F2/F3≈0.16qe(4)

為避免廚房向餐廳串味,可將60%的送風(fēng)量送入餐廳,然后再由餐廳流至廚房。鑒于廚房的通風(fēng)換氣量很大,如此大的補(bǔ)風(fēng)量均經(jīng)餐廳流向廚房,從節(jié)能和管道布置等方面考慮,這種方法并不可取。五、系統(tǒng)布置

1.送風(fēng)系統(tǒng)應(yīng)為直流方式,廚房的通風(fēng)系統(tǒng)宜采用變速風(fēng)機(jī)或關(guān)聯(lián)又風(fēng)機(jī)進(jìn)行送排風(fēng)。2.送排風(fēng)口布置

廚房?jī)?nèi)送、排風(fēng)口的布置應(yīng)按灶具的具體位置加以考慮,不要讓送風(fēng)射流擾亂灶具的排風(fēng)性通。確定送風(fēng)出口的出口風(fēng)速時(shí),在距地2m左右時(shí)的區(qū)域風(fēng)速7、消聲器、靜壓箱總結(jié)

一、概念

(一)消聲器

1。阻式消聲器:是通過(guò)吸聲材料來(lái)吸收聲能降低噪音,一般的微穿孔板消聲器就屬于這個(gè)類型,一般是用來(lái)消除高、中頻噪聲。但是由于結(jié)構(gòu)的原因,在高溫、高濕、高速的情況下不適用。

2?故较暺鳎菏峭ㄟ^(guò)改變截面來(lái)消聲的。我們常用的消聲靜壓箱都是這個(gè)原理。一般降低中、低頻噪音。對(duì)風(fēng)系統(tǒng)沒(méi)有具體的要求。

3。阻抗復(fù)合式:當(dāng)然是結(jié)合二者的結(jié)構(gòu)原理?梢韵椭懈哳l噪音。但是對(duì)風(fēng)系統(tǒng)的要求同阻式消聲器4、對(duì)于一般的民用空調(diào)通風(fēng)系統(tǒng),我個(gè)人認(rèn)為選用阻抗復(fù)合消聲器為好。

阻性消聲器具有良好的中高頻消聲性能。按氣流通道幾何形狀不同,可分為直管式、片式、折板式、迷宮式、蜂窩式、聲流式、障板式、彎頭式等?剐韵暺鬟m用于消除中低頻噪聲或窄帶噪聲。按其作用原理不同,可分為擴(kuò)張式、共振腔式和干涉式等多種型式。阻抗復(fù)合式消聲器,有共振腔、擴(kuò)張室、穿孔屏等聲學(xué)濾波器件,綜合了阻性消聲器良好的中高頻消聲特性和阻抗性消聲器較好的低頻消聲特性,因此其消聲頻帶寬,它是最常用的標(biāo)準(zhǔn)消聲器系列之一。適宜風(fēng)速為6~8米/秒,最高可達(dá)到8~12米,可單獨(dú)使用,也可串聯(lián)使用。消聲效果:低頻10~15dB/m,中頻15~25dB/m,高頻25~30dB/m,平均阻力系數(shù)為0.4。根據(jù)《空氣調(diào)節(jié)》,消聲彎頭,消聲靜壓箱均屬于消聲器的一種。(二)消聲器的作用

消聲器是一種既能允許氣流通過(guò),又能有效地阻止或減弱聲能向外傳播的裝置。

(三)靜壓箱

靜壓箱是送風(fēng)系統(tǒng)減少動(dòng)壓、增加靜壓、穩(wěn)定氣流和減少氣流振動(dòng)的一種必要的配件,它可使送風(fēng)效果更加理想。

(四)靜壓箱的作用

1、可以把部分動(dòng)壓變?yōu)殪o壓使風(fēng)吹得更遠(yuǎn);2、可以降低噪音3、風(fēng)量均勻分配

4、靜壓箱可用來(lái)減少噪聲,又可獲得均勻的靜壓出風(fēng),減少動(dòng)壓損失。而且還有萬(wàn)能接頭的作用。把靜壓箱很好地應(yīng)用到通風(fēng)系統(tǒng)中,可提高通風(fēng)系統(tǒng)的綜合性能。

二、計(jì)算方法

什么NR曲線,聲學(xué)計(jì)算撇開(kāi)不談了,P601也不說(shuō)了。收錄網(wǎng)友言論僅供參考(排名不分先后)!

1、在設(shè)計(jì)靜壓箱時(shí),如果按著規(guī)定的風(fēng)速成進(jìn)行設(shè)計(jì),箱體將會(huì)很大;一般的靜壓箱長(zhǎng)邊要寬出風(fēng)管邊400mm,高度要寬出風(fēng)管高度400mm。數(shù)值是從約克設(shè)計(jì)手冊(cè)上搞來(lái)的,那是估算。

2、靜壓箱一般老工程師的經(jīng)驗(yàn)是5~10db(a)/m,阻抗復(fù)合型(似乎空調(diào)通風(fēng)系統(tǒng)一般都用這個(gè))消聲器10~15db(a)/m

3、控制風(fēng)速在2.5以內(nèi)若體積太大可適當(dāng)?shù)锰岣咭幌嘛L(fēng)速關(guān)于長(zhǎng)度一般大于1米沒(méi)有其他得強(qiáng)制要求4、高度深度=靜壓箱截面面積,靜壓箱截面面積2.5m/s=風(fēng)機(jī)風(fēng)量,至于高度和深度怎么配,自己把握吧~~

5、用你機(jī)組的風(fēng)量L÷3米/秒,可得到你靜壓箱一個(gè)面的面積,然后你根據(jù)你房子的高度,假如是4米,可你的機(jī)組是2米高,在減去軟接頭大概0.5米,上面留高0.5米,那你的靜壓箱只有1米高,那你就可以確定寬度了,有了兩個(gè)數(shù),第三個(gè)數(shù)也就容易確定了,這里最主要的是要看自己的空調(diào)機(jī)房夠不夠位置,如果夠位置就盡量的大點(diǎn)!長(zhǎng)度的計(jì)算方法也是一樣的,你知道了寬度,那么你的寬度乘以長(zhǎng)度不也是有個(gè)面積嗎?這個(gè)面積也要等于L/3,不過(guò)在設(shè)計(jì)院里的面風(fēng)速是取用2m/s的,如果夠空間,就做大點(diǎn)吧。6、靜壓箱厚度最好大于600mm,斷面風(fēng)速小于2m/s,另外注意接出位置與接入位置間有點(diǎn)氣流緩沖區(qū),強(qiáng)烈不建議用靜壓箱,造價(jià)高阻力大,有條件盡量用褲衩三通加消聲彎頭或管道消聲器。

7、我看到過(guò)有很多這樣的設(shè)計(jì)了,起初我不明白他們?yōu)槭裁床挥渺o壓箱,其實(shí)現(xiàn)在說(shuō)的靜壓箱只是鐵皮箱,

第35頁(yè)共95頁(yè)并不是貼有消音棉的靜壓箱,造價(jià)上可能不太緊要,如果真的是貼消音棉的靜壓箱,那就要好好考慮一下成本了,另外的消聲器要注意流速的控制,大部分的都是控制在8m/s以內(nèi),只要能達(dá)到這個(gè)數(shù)值,消音效果也就不錯(cuò)了。

8、我覺(jué)得消聲靜壓箱很有必要,正如棕櫚樹(shù)和尚所說(shuō),在機(jī)房?jī)?nèi)不使用靜壓箱有時(shí)簡(jiǎn)直很難接出管道,消聲只是其次的,斷面風(fēng)速最好小于1.5m/s,高寬比盡量小于1:4;至于阻力,其實(shí)絕大多數(shù)設(shè)計(jì)師都明白,比起風(fēng)管阻力計(jì)算值,我選的風(fēng)機(jī)能力肯定猛男。

9、靜壓箱的作用是把動(dòng)壓變?yōu)殪o壓,均勻分配風(fēng)量,多用于條縫風(fēng)口前

10、我記得北京市建院編的那本技術(shù)措施上好象是說(shuō)以總風(fēng)量計(jì),通過(guò)三個(gè)截面的任一個(gè)速度不得大于1.5m/s

11、我一般選取在4米/秒左右,起個(gè)例子,一個(gè)商場(chǎng),風(fēng)柜24000風(fēng)量,靜壓箱尺寸為201**600*600,貼消音棉,空調(diào)運(yùn)行了一年,效果尚且可以

12、靜壓箱的主要作用就是穩(wěn)壓、降噪。規(guī)范上好像有,靜壓箱內(nèi)的風(fēng)速不大于2.5m/s,根據(jù)風(fēng)量、風(fēng)速就可以確定靜壓箱的容積,靜箱一般是定做的。寬度方向不宜小500mm。通常靜壓箱的尺寸比室內(nèi)機(jī)略小即可。

13、采用地板送風(fēng),它的靜壓箱采用兩種,一種是使用夾層作為靜壓箱,另一種采用普通的靜壓箱然后在靜壓箱上接幾個(gè)風(fēng)管到送風(fēng)口。夾層也能做靜壓箱?

8.風(fēng)管貼吸音材料風(fēng)道的衰減量(日本)

尺寸(內(nèi)部尺寸)630.30.30.31254.63.62.31.61.01.00.60.32503.02.01.61.32.01.61.6頻程Hz5008.56.95.94.93.53.33.9100016.516.715.415.111.87.97.57.26.606.605.101.80201*18.718.014.710.01.64.63.93.96.606.602.701.50400017.415.43.02.00.33.02.32.36.004.501.501.504.010.880002.32.02.34.903.001.601.60風(fēng)管150*150150*300300*300矩300*600形600*600600*900600*1201*00*1800φ1509.風(fēng)管的自然衰減量(只有直風(fēng)道dB/m,其它都是dB)

頻程Hz631250.90.30.302500.30.30.305000.30.30.3510000.30.30.35201*0.30.30.3740000.30.30.35彎管0.601.503.005.400.450.902.104.500.300.601.503.000.120.300.901.80圓φ300形φ600φ1200風(fēng)管尺寸P/A>12P/A=12~5P/A2605101000φ130~2600010000201*000112841015700128410755012341000753123310000533233300000333333300000圓φ260~510形φ510~1000φ1000~201*直徑(mm)斷面積(m)φ1300.02φ2600.06φ5100.26φ10001.0φ201*4.11712841末端反射三通注:P風(fēng)管邊長(zhǎng)之和,mA風(fēng)管斷面積,m2六、防排煙設(shè)計(jì)審查要點(diǎn)

《高規(guī)》-《高層民用建筑設(shè)計(jì)防火規(guī)范》(201*年版)GB50045-95《建規(guī)》-《建筑設(shè)計(jì)防火規(guī)范》(201*年版)GBJ16-87《汽車庫(kù)、修車庫(kù)、停車庫(kù)設(shè)計(jì)防火規(guī)范》GB50067-97《人民防空工程設(shè)計(jì)防火規(guī)范》(201*年版)GB50098-98整理的審查要點(diǎn)如下:

1、防排煙風(fēng)機(jī)、補(bǔ)風(fēng)機(jī)在建筑物內(nèi)部時(shí),應(yīng)設(shè)風(fēng)機(jī)房(上!睹裼媒ㄖ琅艧熂夹g(shù)規(guī)程》3.3.1-2條),如吊裝設(shè)置應(yīng)用具有一定耐火極限的材料做防火保護(hù)。

通風(fēng)機(jī)、新風(fēng)機(jī)組、吊柜式空調(diào)機(jī)均在建筑物內(nèi)部時(shí),是否設(shè)機(jī)房問(wèn)題:應(yīng)據(jù)防火、防爆、風(fēng)機(jī)噪聲、維修管理、更換空氣過(guò)濾器、冷凝水泄漏等因素考慮,一般應(yīng)設(shè)機(jī)房。

2、高規(guī)8.5.7條建規(guī)9.3.13條管道和設(shè)備的保溫材料、消聲材料和粘結(jié)劑應(yīng)為不燃材料或難燃材料。保溫材料一般都有說(shuō)明的,消聲材料和粘結(jié)劑大家比較容易忽視,可在設(shè)計(jì)說(shuō)明中寫(xiě)上。

3、建筑高度超過(guò)50M的一類公共建筑其裙房部分(不超過(guò)24M)靠外墻樓梯間排煙問(wèn)題:按《高規(guī)》6.2.2條處理,如裙房部分封閉樓梯間不能直接天然采光和自然通風(fēng),據(jù)6.2.2.1條規(guī)定,應(yīng)設(shè)防煙樓梯間,設(shè)機(jī)械加壓送風(fēng)系統(tǒng)。

4、高規(guī)5.2.4條“管道穿防火墻時(shí),應(yīng)采用不燃材料將其周圍的空隙填塞密實(shí),不燃材料”-強(qiáng)條。大家設(shè)計(jì)時(shí)可在設(shè)計(jì)施工說(shuō)明或者附注里加上:“管道穿防火墻時(shí),應(yīng)采用不燃材料將其周圍的空隙填塞密實(shí)”。

第37頁(yè)共95頁(yè)

與頻率無(wú)關(guān)A2/A1(%)510152030405080ΔPWL1310875435、《汽車庫(kù)、修車庫(kù)、停車庫(kù)設(shè)計(jì)防火規(guī)范》8.2.7條設(shè)置機(jī)械排煙的汽車庫(kù),最好盡量設(shè)機(jī)械補(bǔ)風(fēng)系統(tǒng),還是因?yàn)榉阑鹁砗熞P(guān)閉的問(wèn)題。江蘇省對(duì)此要求很嚴(yán),不知其他各地的審圖、消防部門的意見(jiàn)是如何的了。排煙口可利用平時(shí)排風(fēng)口,但作為排煙口的排風(fēng)口距室內(nèi)最遠(yuǎn)點(diǎn)不能超過(guò)30M-《汽車庫(kù)、修車庫(kù)、停車庫(kù)設(shè)計(jì)防火規(guī)范》第8.2.3條。

6、建規(guī)9.3.11條規(guī)定防火閥須設(shè)單獨(dú)支架、易熔片應(yīng)能順氣流方向自行嚴(yán)密關(guān)閉-強(qiáng)條。設(shè)計(jì)時(shí)可在設(shè)計(jì)施工說(shuō)明或者附注里加上:“防火閥應(yīng)注意安裝方向,設(shè)單獨(dú)支架!

7、高層建筑大于30M走道只有單側(cè)可開(kāi)啟外窗,應(yīng)采取機(jī)械排煙措施,并應(yīng)滿足《高規(guī)》8.4.5條、8.4.2條及8.4.2條條文說(shuō)明的要求。

8、廠房排煙:依據(jù)工廠生產(chǎn)的火災(zāi)危險(xiǎn)性分類和生產(chǎn)工藝要求及當(dāng)?shù)叵啦块T審查意見(jiàn)辦理。9、吊裝新風(fēng)機(jī)組風(fēng)管不穿過(guò)防火分隔物,在一個(gè)防火分區(qū)內(nèi)可不設(shè)防火閥。(如穿過(guò)普通隔墻時(shí))10、高規(guī)8.4.9條規(guī)定了防熱變形,就必須采用隔熱措施,隔熱層也應(yīng)采用不燃材料,所以安裝在吊頂內(nèi)的排煙管道,應(yīng)采用不燃材料隔熱。

11、地下、半地下汽車庫(kù)平時(shí)排風(fēng)是否要遵循下排2/3,上排1/3的問(wèn)題:不一定了,目前汽車庫(kù)停放汽油車多,燃料為無(wú)鉛汽油,廢氣較空氣輕,排風(fēng)口的布置可據(jù)具體情況處理。

12、《建規(guī)》9.3.12條《高規(guī)》8.5.6條:風(fēng)管軟接頭應(yīng)注明采用不燃材料或難燃材料制成。13、人防工程通風(fēng)強(qiáng)條:

(1)、清潔式、濾毒式通風(fēng)共用風(fēng)機(jī)時(shí)設(shè)增壓管。

(2)、《人防防化規(guī)范》規(guī)定測(cè)壓管必須設(shè)在進(jìn)風(fēng)口部一側(cè),并且必須設(shè)置在防化值班室內(nèi)。

(3)、各類人防口部各防毒通道密閉隔墻上均應(yīng)設(shè)置氣密測(cè)量管,內(nèi)徑50mm,并且兩端應(yīng)有密閉措施。有關(guān)條文的理解、掌握問(wèn)題

1《高規(guī)》GB50045-95第4.1.5A條第4.1.5B.5條《建規(guī)》GBJ16-87第5.1.1A條有關(guān)娛樂(lè)場(chǎng)所設(shè)置防排煙設(shè)施問(wèn)題。低層建筑及高層建筑內(nèi)歌舞廳等場(chǎng)所只要設(shè)在四層及以上或地下一層時(shí),均應(yīng)設(shè)置排煙設(shè)施。其大于20米的內(nèi)走道應(yīng)設(shè)置排煙設(shè)施,具體情況應(yīng)按當(dāng)?shù)叵啦块T要求執(zhí)行。

2《高規(guī)》GB50045-95第5.2.7條《建規(guī)》GBJ16-87第7.2.11條有關(guān)排煙風(fēng)機(jī)設(shè)機(jī)房問(wèn)題。排煙風(fēng)機(jī)宜設(shè)專用風(fēng)機(jī)房。

3《高規(guī)》GB50045-95第8.1.3條有關(guān)高層建筑內(nèi)走道長(zhǎng)度計(jì)算和排煙設(shè)施設(shè)置問(wèn)題。建筑物內(nèi)走道的多條線路中,其中最長(zhǎng)的一條線路長(zhǎng)度即為內(nèi)走道的長(zhǎng)度,當(dāng)該長(zhǎng)度超過(guò)20米時(shí),應(yīng)設(shè)置自然排煙或機(jī)械排煙設(shè)施。

4《高規(guī)》GB50045-95第8.1.3.3條第8.4.1.3條有關(guān)高層建筑中庭自然排煙問(wèn)題。高層建筑中庭凈空高度超過(guò)12米必須設(shè)置機(jī)械排煙設(shè)施(無(wú)論中庭面積大小,或是否具備自然排煙)。如果中庭凈空高度小于12米,第8.2.2.5條規(guī)定可以采用自然排煙方式,其開(kāi)窗面積不應(yīng)小于中庭地面積的5%。

第38頁(yè)共95頁(yè)5《高規(guī)》GB50045-95第8.2.2.3條有關(guān)高層建筑內(nèi)走道面積計(jì)算問(wèn)題。該項(xiàng)內(nèi)走道面積應(yīng)取所有內(nèi)走道面積的總和,內(nèi)走道外窗的面積為各個(gè)可開(kāi)啟外窗面積的總和。

6《高規(guī)》GB50045-95第8.3.7條有關(guān)正壓送風(fēng)余壓計(jì)算問(wèn)題。正壓送風(fēng)系統(tǒng)壓頭損失應(yīng)根據(jù)正在送風(fēng)豎井尺寸及施工質(zhì)量等條件進(jìn)行計(jì)算,應(yīng)按最不利點(diǎn)來(lái)計(jì)算壓頭損失,并充分考慮附加值,計(jì)算書(shū)應(yīng)存檔備查。7《高規(guī)》GB50045-95第6.2.2條第8.3.1條第8.3.2條有關(guān)高層建筑地下室樓梯間防煙設(shè)施設(shè)置問(wèn)題。(1)、樓梯間及合用前室正壓送風(fēng)系統(tǒng)應(yīng)分別設(shè)置獨(dú)立系統(tǒng)。(2)、高層建筑地下一、二層,且地下第二層的地面與室外出入口地面高差不大于10米時(shí),其樓梯間可以不設(shè)機(jī)械加壓送風(fēng)系統(tǒng)的防煙設(shè)施。但應(yīng)征得當(dāng)?shù)叵啦块T許可。(3)、地下室樓梯間及合用前室正壓送風(fēng)系統(tǒng)可與地上系統(tǒng)合用。(4)、若高層建筑地下室樓梯間或合用前室獨(dú)立設(shè)置加壓送風(fēng)系統(tǒng),其送風(fēng)量根據(jù)《高規(guī)》執(zhí)行,建議采取泄壓措施。

8《高規(guī)》GB50045-95第8.4.1條有關(guān)高層建筑設(shè)有氣體滅火設(shè)施是否還需設(shè)機(jī)械排煙設(shè)施問(wèn)題。設(shè)氣體滅火設(shè)施的場(chǎng)所原則上不可以同時(shí)設(shè)機(jī)械排煙設(shè)施。但須按相關(guān)專業(yè)規(guī)范設(shè)置事故通風(fēng)系統(tǒng),在火災(zāi)被撲滅后進(jìn)行排除有害氣體。

9《高規(guī)》GB50045-95第8.4.9條有關(guān)排煙管道隔熱問(wèn)題。吊頂內(nèi)的排煙管道必須采取隔熱措施,隔熱材料應(yīng)采用不燃材料。

10《高規(guī)》GB50045-95第8.5.2條有關(guān)防火分區(qū)內(nèi)風(fēng)管防火閥和垂直風(fēng)管設(shè)置問(wèn)題。(1)、通風(fēng)、空調(diào)系統(tǒng),橫向應(yīng)按每個(gè)防火分區(qū)設(shè)置,即不同防火分區(qū)不能共用一個(gè)風(fēng)系統(tǒng)。(2)、8.5.3.1條規(guī)定管道穿越防火分區(qū)處設(shè)防火閥。如A防火分區(qū)的風(fēng)管道跨越了B防火分區(qū)處應(yīng)設(shè)防火閥,前提是該風(fēng)系統(tǒng)只為A防火分區(qū)設(shè)置,即在B防火分區(qū)不能設(shè)置風(fēng)口。(3)、本層或只穿越一層樓板的垂直風(fēng)管可以不設(shè)在豎井內(nèi),穿越樓層的垂直風(fēng)管應(yīng)設(shè)在豎井內(nèi)。

11《高規(guī)》GB50045-95第8.5.3條《建規(guī)》GBJ16-87第9.3.10條第9.3.14條有關(guān)風(fēng)管防火閥設(shè)置問(wèn)題、加壓(補(bǔ)風(fēng))風(fēng)機(jī)入口設(shè)置防火閥問(wèn)題。(1)、同一防火分區(qū)內(nèi)風(fēng)管穿越機(jī)房隔墻處應(yīng)裝防火閥。如果二個(gè)及其以上機(jī)房與同一豎井相連接均應(yīng)在連接處裝設(shè)防火閥。(2)、穿越重要或火災(zāi)危險(xiǎn)性大的房間應(yīng)設(shè)防火閥。(3)、若高層建筑內(nèi)風(fēng)管穿越變形縫隔墻處的兩側(cè)應(yīng)各裝設(shè)防火閥,無(wú)隔墻的變形縫處可不設(shè)防火閥。(4)、加壓(補(bǔ)風(fēng))風(fēng)機(jī)入口處不必設(shè)置防火,機(jī)械加壓送風(fēng)系統(tǒng)上不宜設(shè)防火閥,若穿過(guò)防火隔墻處應(yīng)采用相應(yīng)防火措施,如提高風(fēng)管耐火等級(jí)等。

12《高規(guī)》GB50045-95第8.5.5條《建規(guī)》GBJ16-87第9.3.12條有關(guān)排風(fēng)管設(shè)置防回流措施問(wèn)題!陡咭(guī)》:廚房、浴室、廁所等的垂直排風(fēng)管道,應(yīng)采取防止回流的措施!督ㄒ(guī)》:公共建筑的廚房、浴室、廁所等的機(jī)械或自然垂直排風(fēng)管道,應(yīng)設(shè)有防止回流的設(shè)施。

13《采暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范》GB50019-201*第5.1.10條有關(guān)房間設(shè)機(jī)械通風(fēng)系統(tǒng)問(wèn)題。沒(méi)有可開(kāi)啟的外窗、但有外門且有人員所在的房間仍應(yīng)設(shè)機(jī)械通風(fēng)系統(tǒng)。

14《采暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范》GB50019-201*第5.1.12條《高規(guī)》GB50045-95第9.1.3條有關(guān)發(fā)

第39頁(yè)共95頁(yè)電機(jī)房設(shè)機(jī)械通風(fēng)系統(tǒng)問(wèn)題。柴油為丙類液體,不屬于易燃易爆物質(zhì),所以柴油發(fā)電機(jī)房不必獨(dú)立設(shè)置排風(fēng)設(shè)施。但儲(chǔ)油間應(yīng)有排風(fēng)設(shè)施,且風(fēng)管穿越儲(chǔ)油間隔墻處應(yīng)設(shè)防火閥。

15《采暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范》GB50019-201*第5.3.4條有關(guān)進(jìn)風(fēng)口位置問(wèn)題。進(jìn)風(fēng)口與排風(fēng)口在同一層,朝向相同且鄰近時(shí),進(jìn)風(fēng)口必須低于排風(fēng)口。不同朝向位置的排風(fēng)口氣流不得回流至進(jìn)風(fēng)口。16《采暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范》GB50019-201*第5.3.14條有關(guān)吸風(fēng)口位置問(wèn)題。(該規(guī)范執(zhí)行有疑義)排除有害氣體和氫氣時(shí),吸風(fēng)口位置必須嚴(yán)格按本條規(guī)范執(zhí)行,排除一般余熱余濕的吸風(fēng)口位置以順利排除余熱余濕為目的。

17《采暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范》GB50019-201*第5.8.5條輸送高溫氣體風(fēng)管熱補(bǔ)償問(wèn)題。應(yīng)根據(jù)風(fēng)管安裝情況進(jìn)行風(fēng)管伸縮量計(jì)算,判定是否采取熱補(bǔ)償措施;火災(zāi)專用的排煙管可不進(jìn)行熱補(bǔ)償。18《采暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范》GB50019-201*第6.2.1條第6.2.15條有關(guān)冷負(fù)荷計(jì)算問(wèn)題。設(shè)計(jì)人員應(yīng)對(duì)空氣調(diào)節(jié)區(qū)進(jìn)行逐項(xiàng)逐時(shí)的冷負(fù)荷計(jì)算,計(jì)算書(shū)存檔備查;同時(shí)應(yīng)把計(jì)算參數(shù)和結(jié)果體現(xiàn)在設(shè)計(jì)說(shuō)明中,注明空調(diào)面積、新風(fēng)量指標(biāo)和冷負(fù)荷計(jì)算結(jié)果。

19《采暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范》GB50019-201*第6.6.3條冷卻水水質(zhì)處理問(wèn)題?諝獾恼舭l(fā)冷卻用水應(yīng)經(jīng)過(guò)處理后以不影響人體健康和設(shè)備使用壽命及不污染地下水等因素考慮.

20《采暖通風(fēng)與空氣調(diào)節(jié)設(shè)計(jì)規(guī)范》GB50019-201*第7.1.5條制冷機(jī)組容量選擇問(wèn)題。電動(dòng)壓縮機(jī)組總裝機(jī)容量按計(jì)算冷負(fù)荷選用,不另外附加。如果計(jì)算冷負(fù)荷與設(shè)備制冷量不完全一致時(shí),宜靠近低一檔冷量選用,跳高一檔選用冷水機(jī)組視為附加。

21《潔凈廠房設(shè)計(jì)規(guī)范》GB50073-201*第6.5.7條有關(guān)走廊設(shè)置防排煙設(shè)施問(wèn)題。潔凈廠房疏散走廊必須設(shè)置機(jī)械排煙設(shè)施,并參照GBJ16-87第5.1.1A條規(guī)定執(zhí)行。條文之外的其它問(wèn)題

1暖通施工圖的地下室高壓配電房和發(fā)電機(jī)房、廚房、衛(wèi)生間通風(fēng)設(shè)計(jì)深度問(wèn)題。有關(guān)安全、衛(wèi)生、環(huán)保、質(zhì)量等問(wèn)題及需要土建配合的問(wèn)題應(yīng)在設(shè)計(jì)時(shí)完成并在施工圖中體現(xiàn)。

2地下室的防煙樓梯間加壓送風(fēng)機(jī)直接設(shè)置在樓梯間或前室是否可行?樓梯間及前室為安全疏散通道不能安裝風(fēng)機(jī)。

3《福建省居住建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)實(shí)施細(xì)則》DBJ13-62-201*第3.2.2條:居住房間室內(nèi)設(shè)計(jì)計(jì)算溫度取值16℃與《住宅設(shè)計(jì)規(guī)范》GB50096-1999中第6.2.2條(強(qiáng)制性條文)要求臥室、起居屋和衛(wèi)生間計(jì)算溫度不低于18℃不符。GB50096-1999第6.2.2條規(guī)定的18℃,是指設(shè)置集中采暖系統(tǒng)的住宅的計(jì)算溫度。DBJ13-62-201*第3.2.2條規(guī)定的16℃設(shè)計(jì)計(jì)算指標(biāo),主要用于住宅的節(jié)能評(píng)定。對(duì)于南方地區(qū)大多數(shù)住宅,住戶冬天采暖一般會(huì)使用形式簡(jiǎn)單的分體式熱泵空調(diào),在這情況下,需要作采暖設(shè)備選型時(shí),可根據(jù)住戶意愿,采用16℃或更高的溫度指標(biāo)。

4《人民防空地下室設(shè)計(jì)規(guī)范》GB50038-94第5.3.3條:人防進(jìn)風(fēng)口宜設(shè)在室外,目前一些人防進(jìn)風(fēng)口設(shè)在

第40頁(yè)共95頁(yè)(防煙)樓梯間內(nèi),存在安全隱患。人防進(jìn)風(fēng)口宜設(shè)在室外,不能設(shè)在戰(zhàn)時(shí)無(wú)法取新風(fēng)的地方。5《汽車庫(kù)、修車庫(kù)、停車場(chǎng)設(shè)計(jì)防火規(guī)范》GB50067-97第8.2.7條,無(wú)直接對(duì)外出口的防火分區(qū),當(dāng)設(shè)置排煙系統(tǒng)時(shí),應(yīng)同時(shí)設(shè)置進(jìn)風(fēng)系統(tǒng),如果該分區(qū)雖有對(duì)外的汽車出口,但設(shè)有防火卷簾,火災(zāi)補(bǔ)風(fēng)是否還要設(shè)置?有直接對(duì)外通道的地下車庫(kù),當(dāng)設(shè)置排煙系統(tǒng)時(shí),可利用對(duì)外通道自然補(bǔ)風(fēng)。

6《人民防空工程設(shè)計(jì)防火規(guī)范》GB50098-98中第4.1.4條和第6.1.3條,高層建筑的地下摩托車庫(kù),自行車庫(kù)排煙應(yīng)依據(jù)何規(guī)范?摩托車庫(kù)按《汽車庫(kù)、修車庫(kù)、停車場(chǎng)設(shè)計(jì)防火規(guī)范》執(zhí)行,如果自行車庫(kù)與汽車庫(kù)在一個(gè)防火分區(qū)內(nèi)也按《汽車庫(kù)、修車庫(kù)、停車場(chǎng)設(shè)計(jì)防火規(guī)范》執(zhí)行,如果按規(guī)范要求需要排煙的,應(yīng)設(shè)置排煙系統(tǒng)。

第五章管道系統(tǒng)設(shè)計(jì)

一、空調(diào)管路系統(tǒng)的設(shè)計(jì)原則

空調(diào)管路系統(tǒng)設(shè)計(jì)主要原則如下:

1.空調(diào)管路系統(tǒng)應(yīng)具備足夠的輸送能力,例如,在中央空調(diào)系統(tǒng)中通過(guò)水系統(tǒng)來(lái)確保渡過(guò)每臺(tái)空調(diào)機(jī)

組或風(fēng)機(jī)盤管空調(diào)器的循環(huán)水量達(dá)到設(shè)計(jì)流量,以確保機(jī)組的正常運(yùn)行;又如,在蒸汽型吸收式冷水機(jī)組中通過(guò)蒸汽系統(tǒng)來(lái)確保吸收式冷水機(jī)組所需要的熱能動(dòng)力。

2.合理布置管道:管道的布置要盡可能地選用同程式系統(tǒng),雖然初投資略有增加,但易于保持環(huán)路的

水力穩(wěn)定性;若采用異程系統(tǒng)時(shí),設(shè)計(jì)中應(yīng)注意各支管間的壓力平衡問(wèn)題。

3.確定系統(tǒng)的管徑時(shí),應(yīng)保證能輸送設(shè)計(jì)流量,并使阻力損失和水流噪聲小,以獲得經(jīng)濟(jì)合理的效果。

眾所周知,管徑大則投資多,但流動(dòng)阻力小,循環(huán)水泵的耗電量就小,使運(yùn)行費(fèi)用降低,因此,應(yīng)當(dāng)確定一種能使投資和運(yùn)行費(fèi)用之和為最低的管徑。同時(shí),設(shè)計(jì)中要杜絕大流量小溫差問(wèn)題,這是管路系統(tǒng)設(shè)計(jì)的經(jīng)濟(jì)原則。

4.在設(shè)計(jì)中,應(yīng)進(jìn)行嚴(yán)格的水力計(jì)算,以確保各個(gè)環(huán)路之間符合水力平衡要求,使空調(diào)水系統(tǒng)在實(shí)際

運(yùn)行中有良好的水力工況和熱力工況。

5.空調(diào)管路系統(tǒng)應(yīng)滿足中央空調(diào)部分負(fù)荷運(yùn)行時(shí)的調(diào)節(jié)要求;6.空調(diào)管路系統(tǒng)設(shè)計(jì)中要盡可能多地采用節(jié)能技術(shù)措施;7.管路系統(tǒng)選用的管材、配件要符合有關(guān)的規(guī)范要求;8.管路系統(tǒng)設(shè)計(jì)中要注意便于維修管理,操作、調(diào)節(jié)方便。9.應(yīng)注意問(wèn)題

(1)放氣排污。在水系統(tǒng)的頂點(diǎn)要設(shè)排氣閥或排氣管,防止形成氣塞;在主立管的最下端(根部)要有排除污物的支管并帶閥門;在所有的低點(diǎn)應(yīng)設(shè)泄水管。

(2)熱脹、冷縮。對(duì)于長(zhǎng)度超過(guò)40m的直管段,必須裝伸縮器。在重要設(shè)備與重要的控制閥前應(yīng)

第41頁(yè)共95頁(yè)裝水過(guò)濾器。

(3)對(duì)于并聯(lián)工作的冷卻塔,一定要安裝平衡管。

(4)注意管網(wǎng)的布局,盡量使系統(tǒng)先天平衡。實(shí)在從計(jì)算上、設(shè)計(jì)上都平衡不了的,適當(dāng)采用平衡閥。

(5)要注意計(jì)算管道推力。選好固定點(diǎn),做好固定支架。特別是大管道水溫高時(shí)更得注意。(6)所有的控制閥門均應(yīng)裝在風(fēng)機(jī)盤管冷凍水的回水管上。(7)注意坡度、坡向、保溫防凍。

二、管路系統(tǒng)的管材

管路系統(tǒng)的管材的選擇可參照下表選用:

介質(zhì)參數(shù)可選用管材DN/溫度/_C200≤450200~500>450500~700>7001.6(YB231-70)螺旋縫電焊鋼管或鋼板卷焊管鋼板卷焊管壓力MPa普通水煤氣鋼管(YB234-63)或無(wú)縫鋼管(YB231-70);無(wú)縫鋼管(YB231-70)螺旋縫電焊鋼管(YB或無(wú)縫鋼管(YB231-70);無(wú)縫鋼管公稱直徑≤1501.0三、供回水總管上的旁通閥與壓差旁通閥的選擇

在變水量水系統(tǒng)中,為了保證流經(jīng)冷水機(jī)組中蒸發(fā)器的冷凍水流量恒定,在多臺(tái)冷水機(jī)組的供回水總管上設(shè)一條旁通管。旁通管上安有壓差控制的旁通調(diào)節(jié)閥。旁通管的最大設(shè)計(jì)流量按一臺(tái)冷水機(jī)組的冷凍水水量確定,旁通管管徑直接按冷凍水管最大允許流速選擇,不應(yīng)未經(jīng)計(jì)算就選擇與旁通閥相同規(guī)格的管徑。當(dāng)空調(diào)水系統(tǒng)采用國(guó)產(chǎn)ZAPB、ZAPC型電動(dòng)調(diào)節(jié)閥作為旁通閥,末端設(shè)備管段的阻力為0.2MPa時(shí),對(duì)應(yīng)不同冷量冷水機(jī)組旁通閥的通徑,可按下表選用:一臺(tái)冷水機(jī)組的140制冷量/kw旁通閥的通徑旁通管公稱直徑407050806510080125100150100201*00201*25201*2525012525015025018035253070088011001230140015801760第42頁(yè)共95頁(yè)冷凍水壓差旁通系統(tǒng)的選擇計(jì)算

在冷凍水循環(huán)系統(tǒng)設(shè)計(jì)中,為方便控制,節(jié)約能量,常使用變流量控制。因?yàn)槔渌畽C(jī)組為運(yùn)行穩(wěn)定,防止結(jié)凍,一般要求冷凍水流量不變,為了協(xié)調(diào)這一對(duì)矛盾,工程上常使用冷凍水壓差旁通系統(tǒng)以保證在末端變流量的情況下,冷水機(jī)組側(cè)流量不變。在這種系統(tǒng)設(shè)計(jì)中,壓差旁通系統(tǒng)的作用是通過(guò)控制壓通旁通閥的開(kāi)度控制冷凍水的旁通流量,從而使供回水干管兩端的壓差恒定。根據(jù)水泵特性我們可得知,泵送壓力恒定時(shí),流量亦保持恒定。

顯然旁通閥3的口徑要滿足最大旁通水量的要求。如一圖,當(dāng)末端負(fù)荷減小時(shí),電動(dòng)二通閥5關(guān)小,供水量減小,而旁通水量增加。當(dāng)旁通水量持繼增加,直到系統(tǒng)負(fù)荷減小到設(shè)計(jì)負(fù)荷的一半,則冷水機(jī)組1關(guān)閉一臺(tái),冷凍水泵2同樣關(guān)閉一臺(tái),供回水壓差減小,旁通閥3再度關(guān)上。因此旁通閥的最大旁通水量就是系統(tǒng)負(fù)荷減小到一臺(tái)冷水機(jī)組停機(jī)時(shí)所需的旁通水量。表面上看,最大旁通水量就是一臺(tái)冷水機(jī)組的額定流量,其實(shí)不然,因?yàn)槔鋬鏊坎⒉灰欢〞?huì)與負(fù)荷同比例匹配,而應(yīng)考慮末端設(shè)備的熱特性與控制方式,如下:

1、采用比例或比例積分控制的空調(diào)器?刂破骶_控制二通

閥的開(kāi)度以調(diào)節(jié)盤管出力。根據(jù)盤管熱特性(如圖二),當(dāng)負(fù)荷減小時(shí),所需流量減小速率更快,當(dāng)負(fù)荷為50%時(shí),水流量?jī)H需13%左右,即旁通水量需87%。

2、風(fēng)機(jī)盤管一般均采用二位控制,二通閥全開(kāi)或全閉,即水流量在設(shè)計(jì)工況下?lián)Q熱。當(dāng)負(fù)荷減小時(shí),水流量同比率減小。甚而小負(fù)荷時(shí),風(fēng)機(jī)盤管可能轉(zhuǎn)至小檔運(yùn)行,風(fēng)量減小,水溫差減小,水流量增大,而旁通水量減小。

在一般系統(tǒng)中,這兩種情況均會(huì)出現(xiàn),此時(shí)就需綜合考慮空調(diào)器與風(fēng)機(jī)盤管水量的比例,部分負(fù)荷時(shí)間,來(lái)選擇旁通閥旁通水量。在一些典型的場(chǎng)合如商場(chǎng),旁通水量甚至?xí)^(guò)一臺(tái)冷水機(jī)組(共三臺(tái)機(jī)組時(shí))額定水量的兩倍。

旁通閥口徑的選擇計(jì)算,在許多文章均有論及,此處簡(jiǎn)述如下:

KvG

G流量。m3/h

Kv流通能力,與所選擇的閥門有關(guān)!鱌阻力損失。Bar

例:一臺(tái)制冷量500RT的冷水機(jī)組,額定冷凍水量302m/h,接管口徑250mm。旁通水量取350m/h,供回水計(jì)算壓差為2bar(約2x105Pa)。DN125旁通閥流通能力250,計(jì)算如下:

33

G(m/h)>350353

250

第43頁(yè)共95頁(yè)

所以采用DN125旁通閥即可滿足要求。旁通閥都具有高流通能力,所以一般其口徑可比冷水機(jī)組接管口徑小二個(gè)規(guī)格。

壓差控制系統(tǒng)的控制方式有比例控制(Honeywell),輸出比例變化的電阻信號(hào),有三位控制(Johnson,Erie),輸出進(jìn)、停、退信號(hào)。比例控制的精度較高,價(jià)格也高,需根據(jù)不同的精度要求選配。兩種方式所配套的執(zhí)行器也不同。

旁通閥執(zhí)行器與閥門需根據(jù)不同的系統(tǒng)壓差,配套不同系列的閥門,例如某品牌VBG閥門+VAT執(zhí)行器適用的最大工作壓差為2bar,而DSGA閥門+MVL執(zhí)行器的最大工作壓差則為8bar。若定貨時(shí)未指明,廠商一般均會(huì)按較高壓差配套。

總之,在壓差旁通系統(tǒng)的選型中,要認(rèn)真考慮各種因素,閥門特性,壓差,流通能力,執(zhí)行器都需考量。在有的工程中,只是簡(jiǎn)單地按冷水機(jī)組口徑選擇旁通閥徑,往往會(huì)造成浪費(fèi)。

四、空調(diào)水系統(tǒng)管徑的確定

水管管徑d由下式確定:

d=

4mw3.14v

式中mw------------水流量,m/s;v------------水流速,m/s

建議,水系統(tǒng)中管內(nèi)水流速按表一中的推薦值選用,經(jīng)試算來(lái)確定其管徑,或按表二根據(jù)流量確定管徑。

表一、管內(nèi)水流速推薦值(m/s)

管徑閉式系統(tǒng)開(kāi)式系統(tǒng)管徑閉式系統(tǒng)開(kāi)式系統(tǒng)150.4~0.50.3~0.41001.3~1.81.2~1.6200.5~0.60.4~0.51251.5~2.01.4~1.8250.6~0.70.5~0.61501.6~2.21.5~2.0320.7~0.90.6~0.8201*.8~2.51.6~2.3

表二、水系統(tǒng)的管徑和單位長(zhǎng)度阻力損失

鋼管管徑/閉式水系統(tǒng)開(kāi)式水系統(tǒng)400.8~1.00.7~0.92501.8~2.61.7~2.4500.9~1.20.8~1.03001.9~2.91.7~2.4651.1~1.40.9~1.23501.6~2.51.6~2.1801.2~1.61.1~1.44001.8~2.61.8~2.3第44頁(yè)共95頁(yè)流量/(m/h)1520253240506580100125150201*503003504004505000~0.50.5~1.01~22~44~66~1111~1818~3232~6565~115115~185185~380380~560560~820820~950950~12501250~15901590~201*kPa/100m0~6010~6010~6010~6010~6010~6010~6010~6010~6010~6010~4710~379~268~238~188~178~158~13流量/(m/h)----0~1.31.3~2.02~44~88~1414~2222~4545~8282~130130~201*00~340340~470470~610610~750750~10001000~1230kPa/100m----0~4311~4010~40--------10~4010~4310~2410~188~158~137~127~127~11五、冷凍水泵揚(yáng)程估算方法

所謂水泵的選取計(jì)算其實(shí)就是估算(很多計(jì)算公式本身就是估算的),估算分的細(xì)致些考慮的內(nèi)容全面些就是精確的計(jì)算。

第45頁(yè)共95頁(yè)特別補(bǔ)充:當(dāng)設(shè)計(jì)流量在設(shè)備的額定流量附近時(shí),上面所提到的阻力可以套用,更多的是往往都大過(guò)設(shè)備的額定流量很多。同樣,水管的水流速建議計(jì)算后,查表取阻力值。

關(guān)于水泵揚(yáng)程過(guò)大問(wèn)題。設(shè)計(jì)選取的水泵揚(yáng)程過(guò)大,將使得富裕的揚(yáng)程換取流量的增加,流量增加才使得水泵噪音加大。特別的,流量增加還使得水泵電機(jī)負(fù)荷加大,電流加大,發(fā)熱加大,“換過(guò)無(wú)數(shù)次軸承”還是小事,有很大可能還要燒電機(jī)的。

另外“水泵出口壓力只有0.22兆帕”能說(shuō)明什么呢?水泵進(jìn)出口壓差才是問(wèn)題的關(guān)鍵。例如將開(kāi)式系統(tǒng)的水泵放在100米高的頂上,出口壓力如果是0.22MPa,就這個(gè)系統(tǒng)將水泵放在地上向100米高的頂上送,出口壓力就是0.32MPa了!

1、水泵揚(yáng)程簡(jiǎn)易估算法

暖通水泵的選擇:通常選用比轉(zhuǎn)數(shù)ns在130~150的離心式清水泵,水泵的流量應(yīng)為冷水機(jī)組額定流量的1.1~1.2倍(單臺(tái)取1.1,兩臺(tái)并聯(lián)取1.2。按估算可大致取每100米管長(zhǎng)的沿程損失為5mH2O,水泵揚(yáng)程(mH2O):

Hmax=△P1+△P2+0.05L(1+K)

△P1為冷水機(jī)組蒸發(fā)器的水壓降。

△P2為該環(huán)中并聯(lián)的各占空調(diào)未端裝置的水壓損失最大的一臺(tái)的水壓降。L為該最不利環(huán)路的管長(zhǎng)

K為最不利環(huán)路中局部阻力當(dāng)量長(zhǎng)度總和和與直管總長(zhǎng)的比值,當(dāng)最不利環(huán)路較長(zhǎng)時(shí)K值取0.2~0.3,最不利環(huán)路較短時(shí)K值取0.4~0.6

2、冷凍水泵揚(yáng)程實(shí)用估算方法

這里所談的是閉式空調(diào)冷水系統(tǒng)的阻力組成,因?yàn)檫@種系統(tǒng)是最常用的系統(tǒng)。1.冷水機(jī)組阻力:由機(jī)組制造廠提供,一般為60~100kPa。

2.管路阻力:包括磨擦阻力、局部阻力,其中單位長(zhǎng)度的磨擦阻力即比摩組取決于技術(shù)經(jīng)濟(jì)比較。若取值大則管徑小,初投資省,但水泵運(yùn)行能耗大;若取值小則反之。目前設(shè)計(jì)中冷水管路的比摩組宜控制在150~200Pa/m范圍內(nèi),管徑較大時(shí),取值可小些。

3.空調(diào)未端裝置阻力:末端裝置的類型有風(fēng)機(jī)盤管機(jī)組,組合式空調(diào)器等。它們的阻力是根據(jù)設(shè)計(jì)提出的空氣進(jìn)、出空調(diào)盤管的參數(shù)、冷量、水溫差等由制造廠經(jīng)過(guò)盤管配置計(jì)算后提供的,許多額定工況值在產(chǎn)品樣本上能查到。此項(xiàng)阻力一般在20~50kPa范圍內(nèi)。

4.調(diào)節(jié)閥的阻力:空調(diào)房間總是要求控制室溫的,通過(guò)在空調(diào)末端裝置的水路上設(shè)置電動(dòng)二通調(diào)節(jié)閥是實(shí)現(xiàn)室溫控制的一種手段。二通閥的規(guī)格由閥門全開(kāi)時(shí)的流通能力與允許壓力降來(lái)選擇的。如果此允許壓力降取值大,則閥門的控制性能好;若取值小,則控制性能差。閥門全開(kāi)時(shí)的壓力降占該支路總壓力降的百分?jǐn)?shù)被稱為閥權(quán)度。水系統(tǒng)設(shè)計(jì)時(shí)要求閥權(quán)度S>0.3,于是,二通調(diào)節(jié)閥的允許壓力降一般不小于40kPa。根據(jù)以上所述,可以粗略估計(jì)出一幢約100m高的高層建筑空調(diào)水系統(tǒng)的壓力損失,也即循環(huán)水泵所需的揚(yáng)程:

1.冷水機(jī)組阻力:取80kPa(8m水柱);

第46頁(yè)共95頁(yè)設(shè)備阻力損失

設(shè)備名稱阻力(kPa)備注離心式冷凍機(jī)蒸發(fā)器冷凝器30~8050~80按不同產(chǎn)品而定按不同產(chǎn)品而定吸收式冷凍機(jī)蒸發(fā)器40~100按不同產(chǎn)品而定冷凝器冷卻塔50~14020~80按不同產(chǎn)品而定不同噴霧壓力冷熱水盤管20~50水流速度在0.8~1.5m/s左右熱交換器風(fēng)機(jī)盤管機(jī)組20~5010~20風(fēng)機(jī)盤管容量愈大,阻力愈大,最大30kPa左右自動(dòng)控制閥30~502.管路阻力:取冷凍機(jī)房?jī)?nèi)的除污器、集水器、分水器及管路等的阻力為50kPa;取輸配側(cè)管路長(zhǎng)度300m與比摩阻200Pa/m,則磨擦阻力為300*200=60000Pa=60kPa;如考慮輸配側(cè)的局部阻力為磨擦阻力的50%,則局部阻力為60kPa*0.5=30kPa;系統(tǒng)管路的總阻力為50kPa+60kPa+30kPa=140kPa(14m水柱);

3.空調(diào)末端裝置阻力:組合式空調(diào)器的阻力一般比風(fēng)機(jī)盤管阻力大,故取前者的阻力為45kPa(4.5水柱);

4.二通調(diào)節(jié)閥的阻力:取40kPa(0.4水柱)。

5.于是,水系統(tǒng)的各部分阻力之和為:80kPa+140kPa+45kPa+40kPa=305kPa(30.5m水柱)6.水泵揚(yáng)程:取10%的安全系數(shù),則揚(yáng)程H=30.5m*1.1=33.55m。

根據(jù)以上估算結(jié)果,可以基本掌握類同規(guī)模建筑物的空調(diào)水系統(tǒng)的壓力損失值范圍,尤其應(yīng)防止因未經(jīng)過(guò)計(jì)算,過(guò)于保守,而將系統(tǒng)壓力損失估計(jì)過(guò)大,水泵揚(yáng)程選得過(guò)大,導(dǎo)致能量浪費(fèi)。

第47頁(yè)共95頁(yè)3、水泵揚(yáng)程設(shè)計(jì)

(1)冷、熱水管路系統(tǒng)

開(kāi)式水系統(tǒng)Hp=hf+hd+hm+hs(10-12)閉式水系統(tǒng)Hp=hf+hd+hm(10-13)

式中hf、hd水系統(tǒng)總的沿程阻力和局部阻力損失,Pa;hm設(shè)備阻力損失,Pa;

hs開(kāi)式水系統(tǒng)的靜水壓力,Pa。

hd/hf值,小型住宅建筑在1~1.5之間;大型高層建筑在0.5~1之間;遠(yuǎn)距離輸送管道(集中供冷)在0.2~0.6之間。設(shè)備阻力損失見(jiàn)表10-5。

六、冷卻水系統(tǒng)的設(shè)計(jì)

目前最常用的冷卻水系統(tǒng)設(shè)計(jì)方式是冷卻塔設(shè)在建筑物的屋頂上,空調(diào)冷凍站設(shè)在建筑物的底層或地下室。水從冷卻塔的集水槽出來(lái)后,直接進(jìn)入冷水機(jī)組而不設(shè)水箱。當(dāng)空調(diào)冷卻水系統(tǒng)僅在夏季使用時(shí),該系統(tǒng)是合理的,它運(yùn)行管理方便,可以減小循環(huán)水泵的揚(yáng)程,節(jié)省運(yùn)行費(fèi)用。為了使系統(tǒng)安全可靠的運(yùn)行,實(shí)際設(shè)計(jì)時(shí)應(yīng)注意以下幾點(diǎn):

1.冷卻塔上的自動(dòng)補(bǔ)水管應(yīng)稍大一點(diǎn),有的按補(bǔ)水能力大于2倍的正常補(bǔ)水量設(shè)計(jì);

2.在冷卻水循環(huán)泵的吸入口段再設(shè)一個(gè)補(bǔ)水管,這樣可縮短補(bǔ)水時(shí)間,有利于系統(tǒng)中空氣的排出;3.冷卻塔選用蓄水型冷卻塔或訂貨時(shí)要求適當(dāng)加大冷卻塔的集水槽的貯水能力;

4.應(yīng)設(shè)置循環(huán)泵的旁通止逆閥,以避免停泵時(shí)出現(xiàn)從冷卻塔內(nèi)大量溢水問(wèn)題,并在突然停電時(shí),防止

系統(tǒng)發(fā)生水擊現(xiàn)象;

5.設(shè)計(jì)時(shí)要注意各冷卻塔之間管道阻力平衡問(wèn)題;按管時(shí),注意各塔至總干管上的水力平衡;供水支

管上應(yīng)加電動(dòng)閥,以便在停某臺(tái)冷卻塔時(shí)用來(lái)關(guān)閉;

6.并聯(lián)冷卻塔集水槽之間設(shè)置平衡管。管徑一般取與進(jìn)水干管相同的管徑,以防冷卻塔集水槽內(nèi)水

位高低不同。避免出現(xiàn)有的冷卻塔溢水,還有冷卻塔在補(bǔ)水的現(xiàn)象。

1、冷卻水系統(tǒng)的補(bǔ)水量

現(xiàn)在的資料給出的冷卻水系統(tǒng)的補(bǔ)水量數(shù)據(jù)判別較大,見(jiàn)下表:

補(bǔ)水量電動(dòng)制冷時(shí)補(bǔ)水量為循環(huán)量的1.53%,吸收式制冷時(shí)為循環(huán)水量的2.08%;粗略估算取2%~3%取循環(huán)水量的1%~1.5%取循環(huán)水量的1%~3第48頁(yè)共95頁(yè)吸收制冷時(shí)取循環(huán)水量的2%~3%取循環(huán)水量的0.3~1%平均補(bǔ)水量為循環(huán)水量的2.5%,當(dāng)機(jī)組運(yùn)行時(shí)間長(zhǎng)且運(yùn)行時(shí)需換水1~2次時(shí),補(bǔ)水量可達(dá)3%~5%電動(dòng)冷水機(jī)組,補(bǔ)水量約為循環(huán)量的1.4%~1..6%;吸收式冷水機(jī)組時(shí),補(bǔ)水量為循環(huán)水量的2%~3%電動(dòng)制冷取循環(huán)水量的1.2%~1.6%;吸收式制冷為1.4%~1.8%經(jīng)對(duì)表中資料的分析,從理論上說(shuō),如把水冷卻5_C,蒸發(fā)的水量不到被冷卻水量的1%。但是,實(shí)際上還應(yīng)考慮排污量和由于空氣夾水滴的飄溢損失;同時(shí),還應(yīng)綜合考慮各種因素(如冷卻塔的結(jié)構(gòu)、冷卻水水泵的揚(yáng)程、空調(diào)系統(tǒng)的大部分時(shí)間里是在部分負(fù)荷下運(yùn)行等)的影響。我們建議:電動(dòng)制冷時(shí),冷卻塔的補(bǔ)水量取為冷卻水流量的1%~2%;溴化鋰吸收式冷水機(jī)組的補(bǔ)水量取為冷卻水流量的2%~2.5%。

2、冷卻水循環(huán)系統(tǒng)設(shè)計(jì)中應(yīng)注意的幾個(gè)問(wèn)題:

1.電動(dòng)冷水機(jī)組的冷凝器進(jìn)、出水溫差一般為5_C,雙效溴化鋰吸收式冷水機(jī)組冷卻水進(jìn)、出口溫差一般為6~6.5_C,因此,在選用冷卻塔時(shí),電動(dòng)冷水機(jī)組宜選普通型冷卻塔(Δt=5_C);而雙效溴化鋰吸收式冷水機(jī)組宜選中溫型冷卻塔(Δt=8_C);

2.選用冷卻塔時(shí)應(yīng)遵循《工業(yè)企業(yè)噪音控制設(shè)計(jì)規(guī)范》(GBJ87-85)的規(guī)定,其噪聲不得超過(guò)下表所列的噪聲限制值》:廠界噪聲限制值/dB(A)

廠界毗鄰區(qū)域的環(huán)境類別特殊住宅區(qū)居民、文教區(qū)一類混合區(qū)商業(yè)中心、二類混合區(qū)工業(yè)集中區(qū)交通干線道路兩側(cè)晝間455050606570夜間354045505555備注高級(jí)賓館和療養(yǎng)院學(xué)校與居民區(qū)工商業(yè)與居民混合區(qū)商業(yè)繁華區(qū)與居民混合區(qū)工廠林立區(qū)域每小時(shí)車流100輛以上七、冷凝水管道設(shè)計(jì)

通常,可以根據(jù)機(jī)組的冷負(fù)荷Q(kW)按下列數(shù)據(jù)近似選定冷凝水管的公稱直徑;

Q≤7kWDN=20mmQ=7.1~17.6kWDN=25mm第49頁(yè)共95頁(yè)Q=101~176kWDN=40mmQ=177~598kWDN=50mmQ=599~1055kWDN=80mmQ=1056~1512kWDN=100mmQ=1513~12462kWDN=125mmQ>12462kWDN=150mm注:(1)DN=15mm的管道,不推薦使用。

(2)立管的公稱直徑,就與水平干管的直徑相同。

風(fēng)機(jī)盤管機(jī)組、整體式空調(diào)器、組合式空調(diào)機(jī)組等運(yùn)行過(guò)程中產(chǎn)生的冷凝水,必須及時(shí)予以排走。排放冷凝水管道的設(shè)計(jì),應(yīng)注意以下事項(xiàng):

沿水流方向,水平管道應(yīng)保持不小于千分之一的坡度;且不允許有積水部位。

當(dāng)冷凝水盤位于機(jī)組負(fù)壓區(qū)段時(shí),凝水盤的出水口處必須設(shè)置水封,水封的高度應(yīng)比凝水盤處的負(fù)壓(相當(dāng)于水柱溫度)大50%左右。水封的出口,應(yīng)與大氣相通。

為了防止冷凝水管道表面產(chǎn)生結(jié)露,必須進(jìn)行防結(jié)露驗(yàn)算。

注:(1)采用聚氯乙烯塑料管時(shí),一般可以不必進(jìn)行防結(jié)露的保溫和隔汽處理。

(2)采用鍍鋅鋼管時(shí),一般應(yīng)進(jìn)行結(jié)露驗(yàn)算,通常應(yīng)設(shè)置保溫層。

冷凝水立管的頂部,應(yīng)設(shè)計(jì)通向大氣的透氣管。

設(shè)計(jì)和布置冷凝水管路時(shí),必須認(rèn)真考慮定期沖洗的可能性,并應(yīng)設(shè)計(jì)安排必要的設(shè)施。冷凝水管的公稱直徑DN(mm),應(yīng)根據(jù)通過(guò)冷凝水的流量計(jì)算確定。

一般情況下,每1kW冷負(fù)荷每1h約產(chǎn)生0.4kg左右冷凝水;在潛熱負(fù)荷較高的場(chǎng)合,每1kW冷負(fù)荷每1h約產(chǎn)生0.8kg冷凝水。

八、分汽缸、分水器、集水器尺寸的確定

1、

直徑D

(1)按斷面流速v確定D:分汽缸按斷面流速8-10m/s計(jì)算;分水器、集水器按斷面流速0.1m/s計(jì)算。(2)按經(jīng)驗(yàn)估算確定D:D=1.5-3dmax式中D分汽缸、分水器、集水器直徑,mm;

dmax分汽缸、分水器、集水器支管中的最大直徑,mm。2、

配管間距L1\\L2\\L3……

分汽缸、分水器、集水器配管尺寸表(mm)

管徑d1d2d3d4L1尺寸L2L3L4L5LL6D編號(hào)第50頁(yè)共95頁(yè)

友情提示:本文中關(guān)于《暖通空調(diào)設(shè)計(jì)方案經(jīng)驗(yàn)總結(jié)_secret》給出的范例僅供您參考拓展思維使用,暖通空調(diào)設(shè)計(jì)方案經(jīng)驗(yàn)總結(jié)_secret:該篇文章建議您自主創(chuàng)作。

來(lái)源:網(wǎng)絡(luò)整理 免責(zé)聲明:本文僅限學(xué)習(xí)分享,如產(chǎn)生版權(quán)問(wèn)題,請(qǐng)聯(lián)系我們及時(shí)刪除。


暖通空調(diào)設(shè)計(jì)方案經(jīng)驗(yàn)總結(jié)_secret》由互聯(lián)網(wǎng)用戶整理提供,轉(zhuǎn)載分享請(qǐng)保留原作者信息,謝謝!
鏈接地址:http://m.seogis.com/gongwen/659723.html